Permit Number | BLD17-00744 |
Status | Finaled |
Name |
LAYTON CONSTRUCTION
|
Site Address |
3201 W AIRPORT WAY
|
Project Name | Loading Walkway at Gate C11 |
Customer Number | |
ePlanReview | Yes |
Description |
(ELEVATED AIRCRAFT PASSENGER LOADING WALKWAY – WEST GROUND LEVEL LOADING PEDESTRIAN WALKWAY – GATE C11 – BOISE AIRPORT) The ground level loading pedestrian walkway does not have a fire sprinkler system. To construct an elevated aircraft passenger loading walkway. A 157 square feet portion of the existing concrete tarmac will be removed to install a new 2.0 feet thick, 12.5 feet by 12.5 feet concrete base to support the new elevated, telescoping, and rotating aircraft passenger loading walkway. Anchor bolts are 2.25 inches in diameter and will be embedded 1.5 feet into the concrete. The existing passenger boarding door in the wall of the ground level loading pedestrian walkway at former Gate C11 will have all hardware removed and will be welded shut. A new Gate C11 will be created in a different location to provide access to the new elevated aircraft passenger loading walkway. A new column will be provided in the wall of the ground level loading pedestrian walkway to resist out of plane lateral loads at the new door. New work is to include an interior concrete ramp within the ground level loading pedestrian walkway sloped at 1 unit vertical to 12 units horizontal with a level landing at 30 feet maximum and handrails on each side; a new 4 foot wide door at new Gate C11 with level landings on each side; a fixed, elevated, and enclosed aircraft passenger loading walkway ramp sloped at 1 unit vertical to 12 units horizontal with level landings at 30 feet maximum and handrails on each side having a floor area of about 435 square feet and a length of about 68 feet; and an elevated, enclosed, telescoping, and rotating aircraft passenger loading walkway sloped no steeper than 1 unit vertical to 20 units horizontal having a maximum floor area of about 600 square feet and a maximum length of about 105 feet. Special Inspection is required for concrete, welding, and for post installed anchors in hardened concrete. Supports for the fixed aircraft passenger loading walkway ramp will be attached to the existing concrete tarmac. The structural design by the manufacturer for the fixed and for the rotating aircraft passenger loading walkway, including support elements and attachments, are a deferred submittal item. The work is required to comply with the approved drawings, with the structural design, with the plan review report, with NFPA 415, and with all applicable codes and ordinances. This permit is intended to establish a Certificate of Occupancy only for the new aircraft passenger loading walkway. **CJW**
|