Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberBLD17-00787
StatusFinaled
Name IDAC LLC
Site Address 211 N BACON DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Modification - Converting 240sq' of existing garage to a living space (Office) 10/21/19 **JAB** PHASE 2 - 2ND FLOOR NOW BEING ADDED, 865sq' OF MASTER SUITE & 128sq' OF 2ND LEVEL DECK 4.8.19 **jab** Phase 1 - Permit to remove existing loadbearing walls separating the kitchen from the living room and replace with beam and piers. Also construct the foundation, floor and walls for, new laundry room, mud room and half bath. This first phase is approximately 360 sq. ft. of new living space. Once applicant has obtained engineering for the Phase 2, to add 867 sq. ft. for a second floor to be located above the existing garage. Phase 2 will contain a master bedroom, full bath, office/loft and walk-in closet and 2nd floor deck. No plan review has been performed on phase 2 of the project. Electrical, plumbing and HVAC permits shall be pulled separately. The work will be performed per the approved plans, engineered documents and local codes. All new construction shall comply with current energy codes. Manual J will be submitted and reviewed by the city prior to approval of the plan modification for phase 2. **DAF**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/2/20201/3/20201/3/2020APASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Chris Homeyer
DOC - Permit Finaled1/3/20201/3/20201/3/2020PPASS
DetailsBrandon Shaw
BLD-Energy code compliance11/7/201911/8/201911/8/2019APASS
DetailsBrandon Shaw
Insulation Inspection Phone #: ###-#### Inspection requested via web by Chris Homeyer
BLD-Energy code compliance10/29/201910/30/201910/30/2019APASS
DetailsBrandon Shaw
OK to insulate...
BLD-Conference10/10/201910/11/201910/11/2019ADONE
DetailsBrandon Shaw
Mike will be available at site
Garage framing conference Phone #: ###-#### Inspection requested via web by Chris Homeyer
BLD-Energy code compliance7/16/20197/16/20197/16/2019APASS
DetailsBrandon Shaw
Insulation inspection 2nd floor...if needed Phone #: ###-#### Inspection requested via web by Chris Homeyer
BLD-Framing/Rough-in7/11/20197/11/20197/11/2019PPASS
DetailsBrandon Shaw
2nd floor rough framing and energy seal...
OK to insulate...
BLD-Energy code compliance6/27/20196/27/20196/27/2019ACANC
DetailsMike Jordan
Tyvec inspection Phone #: ###-#### Inspection requested via web by Chris Homeyer
BLD-Conference6/27/20196/27/20196/27/2019ADONE
DetailsMike Jordan
Tyvec inspection Phone #: ###-#### Inspection requested via web by Chris Homeyer. Framing walk through only.
BLD-Framing/Rough-in6/27/20196/27/20196/27/2019ACANC
DetailsDave Hannah
2nd floor framing and tyvec Phone #: ###-#### >> Inspection requested via web by Chris Homeyer Inspection cancelled from web by: Chris Homeyer
BLD-Wall Bracing6/13/20196/13/20196/13/2019APASS
DetailsDave Hannah
Shear inspection 2nd level Phone #: ###-#### Inspection requested via web by Chris Homeyer
BLD-Foundation4/12/20194/12/20194/12/2019PPASS
DetailsDave Hannah
Have sona tubes filled front and back wanting to back fill. Thanks Phone #: ###-#### Inspection requested via web by Chris Homeyer
BLD-Footing4/10/20194/10/20194/10/2019APASS
DetailsDave Hannah
Hole inspection Phone #: ###-#### Inspection requested via web by Chris Homeyer
BLD-Aging Inspection3/7/20183/7/20183/8/2018 DONE
DetailsDave Hannah
BLD-Aging Inspection3/8/20183/8/20183/8/2018 PEND
DetailsDave Hannah
BLD-Aging Inspection10/20/201710/20/201710/24/2017 PASS
DetailsDave Hannah
BLD-Aging Inspection10/19/201710/19/201710/24/2017 PASS
DetailsDave Hannah
BLD-Energy code compliance6/6/20176/7/20176/7/2017APASS
DetailsDave Hannah
Steve Phone #: ###-####
BLD-Framing/Rough-in6/5/20176/5/20176/6/2017PPART
DetailsDave Hannah
Steve Phone #: ###-#### phase one kitchen master bed room ok to insulate
BLD-Wall Bracing5/16/20175/17/20175/17/2017APASS
DetailsDave Hannah
St4eve Phone #: ###-####
BLD-Foundation4/17/20174/18/20174/18/2017APART
DetailsDave Hannah
Steve Phone #: ###-####
BLD-Footing4/12/20174/13/20174/13/2017APASS
DetailsBrandon Shaw
Steve Phone #: ###-####