Permit Information
Permit NumberBLD17-00849
StatusFinaled
Name LAYTON CONSTRUCTION
Site Address 6895 S EISENMAN RD Unit: 110
Project NamePODS
Customer Number 
ePlanReviewYes
Description
(PODS – PORTABLE SELF STORAGE CONTAINER WAREHOUSE) (DRH16-00124) (CZC17-00082) The fire sprinkler system is used for unlimited area of the building. To create a 36,243 square foot tenant space within a new 52,000 square foot building. Work is to include a tenant demising wall, suspended ceilings within the office area, gypsum board ceilings at the toilet rooms, a new 20 feet by 20 feet overhead door opening in the South exterior wall (former opening was 12 feet wide by 14 feet high), and bollards. Two existing exterior tilt-up concrete panels will be modified to accommodate the larger overhead door opening and new steel columns and beams will be installed on the inside of the wall to resist out of plane lateral loads. Steel plates will be installed to reinforce panel to panel joints above the enlarged opening. Special Inspection is required for welding and for post installed anchors in hardened concrete. The accessible restrooms and office area were constructed under shell permit BLD16-02176. The accessible drinking fountains and the service sink were also installed under that permit. A separate racking permit is required for racks over 8 feet in height. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/12/20176/13/20176/13/2017PPASS
DetailsJim Storey
Brent Phone #: ###-#### no racking
FIRE-Final Inspection6/12/20176/13/20176/13/2017APASS
DetailsJim Page
Fire sprinkler inspection is complete, fire alarm inspection for building is complete, fire extinguishers are in place with current inspection tags. Final life fire safety inspection passed/complete.
FIRE-Final Inspection6/8/20176/9/20176/9/2017AFAIL
DetailsTroy Cobbley
Need fire extinguisher at office and an exit sign in the office at the main entry doors, need exit signs as per plans and discussion in the warehouse area, needs missing door installed and panic hardware.
FIRE-Final Inspection6/1/20176/2/20176/2/2017PFAIL
DetailsJim Page
Fire life safety cannot be completed for this permit until the fire sprinkler/fire alarm (FIR16-00724 for fire alarm and FIR16-00705 for fire sprinkler) permits for core and shell are complete as well as the BLD (BLD16-02176) permit for core and shell is complete. After core and shell permits are passed then the FIR permit (FIR17-00190) for fire sprinklers associated with this project will need to be completed before life fire safey inspection can be performed.
BLD-Ceiling Grid Inspection5/31/20175/31/20175/31/2017PPASS
DetailsDave Hannah
Brent Phone #: ###-####