Permit Information
Permit NumberBLD17-01479
StatusFinaled
Name CANNING CONSTRUCTION INC
Site Address 8011 W USTICK RD
Project NameIdaho High School Activities
Customer NumberBLD17-01956
ePlanReviewYes
Description
(IDAHO HIGH SCHOOL ACTIVITIES – ENCLOSING OPEN AREA – WEST END OF BUILDING) (DRH16-00376) (12-19-17 PLAN MODIFICATION TO INSTALL WIDE FLANGE STEEL BEAMS ABOVE NEW OPENINGS IN AN INTERIOR MASONRY SHEAR WALL. TENSION PLATES WILL BE INSTALLED TO CONNECT THE BEAMS FROM END TO END SO THAT THE BEAMS AND STRAPS WILL ALL FUNCTION AS A DRAG STRUT. THIS REPLACES THE FORMERLY PROPOSED MASONRY LINTELS WITH STEEL ANGLES ON EACH SIDE ABOVE NEW OPENINGS. SPECIAL INSPECTION IS REQUIRED FOR WELDING. AT ANOTHER LOCATION, AN EXISTING COLUMN WILL BE CONCEALED BY AN EXTERIOR FURRED OUT WALL. IN ADDITION, THE HEIGHT OF THE TRASH ENCLOSURE WALLS WILL BE REDUCED FROM 7’- 4” TO 6’- 0”.) Drawings for permits BLD17-01479 and BLD17-01956 are filed under BLD17-01479 in ePlanReview. This building does not have a fire sprinkler system. To enclose a 998 square foot covered area that is part of a 6,424 square foot existing building. The roof structure above will remain. Work is to include concrete footings, concrete foundation stem walls, concrete slabs on grade, masonry exterior walls with interior continuous insulation, wood frame exterior walls with R-19 insulation, exterior windows, exterior door, interior doors, interior windows, millwork, and finishes. Special Inspection is required for concrete, masonry, and for post installed anchors in hardened concrete. This permit is intended to establish a new Certificate of Occupancy for the entire building. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/19/20186/20/20186/20/2018APASS
DetailsJim Sly
Greg Phone #: ###-####
OK for Perm Occ.
FIRE-Final Inspection5/2/20185/2/20185/2/2018PPASS
DetailsTroy Cobbley
Life safety passed

Greg Phone #: ###-####
BLD-Final3/2/20183/2/20183/2/2018PPART
DetailsJim Sly
Greg Phone #: ###-####
Phase 1 ......OK.
FIRE-Final Inspection3/2/20183/2/20183/2/2018PPART
DetailsTroy Cobbley
Phase 1 area life safety passed.

Greg Phone #: ###-####
FIRE-Conference2/23/20182/23/20182/23/2018PDONE
DetailsTroy Cobbley
We discussed life safety requirements. I noted that the wrong remote annunciator had been installed for the duct smoke detector and that the exit discharge light was missing at the west exit door.

Greg Phone #: ###-####
BLD-Other2/13/20182/13/20182/13/2018PPASS
DetailsJim Sly
Tbar grid - Greg Phone #: ###-####
BLD-Energy code compliance1/22/20181/22/20181/22/2018PPASS
DetailsJim Sly
Greg Phone #: ###-####
BLD-Framing/Rough-in1/17/20181/18/20181/18/2018APASS
DetailsJim Sly
Greg Phone #: ###-####
BLD-Framing/Rough-in1/8/20181/8/20181/8/2018PPASS
DetailsJim Sly
Jeff-Ceiling Rough Framing Phone #: ###-#### Inspection requested via web by Jeff Canning
BLD-Other12/29/20171/2/20181/2/2018PDONE
DetailsJim Sly
Jeff-CMU inspection Phone #: ###-####
CMU Completed. OK pending all inspections, tests and approval by Geotek.
BLD-Other12/26/201712/27/201712/27/2017APASS
DetailsJim Sly
cmu inspection // Jeff Phone #: ###-####
CMU final lift OK pending Geotek special inspection, tests and approvals.
BLD-Footing11/20/201711/20/201711/20/2017PPASS
DetailsJim Sly
Jeff Phone #: ###-####
OK pending Geotek special inspection, tests and approvals.