Information based on query as of Thursday, June 27, 2024.
Permit Information
Permit NumberBLD17-01546
StatusFinaled
Name LAYTON CONSTRUCTION
Site Address 6895 S EISENMAN RD Unit: 120
Project NameBurgin Relocation, Inc.
Customer Number 
ePlanReviewYes
Description
(BURGIN RELOCATION INC. – EAST END OF BUILDING) (DRH16-00124) (CZC17-00082) The fire sprinkler system is used for unlimited area of the building. To construct interior improvements within a 14,015 square foot tenant space located within a new 52,756 square foot building. The tenant demising wall was constructed under permit BLD17-00849. Work is to include interior nonbearing walls, two toilet rooms accessible to the disabled, metal ceiling joists and gypsum board deck above the office area (not designed for any use), suspended acoustical ceilings within the office area, gypsum board ceilings at the toilet rooms, a concrete slab on grade, interior doors, and finishes. Special Inspection is required for welding and for post installed anchors in hardened concrete. A separate racking permit is required for racks over 8 feet in height. Gypsum shear wall fasteners are required to be spaced 7 inches maximum on center. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final8/10/20178/11/20178/11/2017PPASS
DetailsJim Storey
tyler Phone #: ###-####
FIRE-Final Inspection8/10/20178/11/20178/11/2017PPASS
DetailsJim Page
Fire sprinkler inspection complete, no fire alarm modifications, fire extinguishers are in place with current inspection tags. Final lfie fire safety inspection for area of work passed/complete.
BLD-Ceiling Grid Inspection8/9/20178/10/20178/10/2017PPASS
DetailsJim Storey
Tyler Phone #: ###-####
FIRE-Final Inspection8/8/20178/9/20178/9/2017PCANC
DetailsJim Page
Inspection request cancelled, space not ready for final life fire safety inspection, office spaces are missing the ceiling tile, ceiling tile provides heat collection for fire sprinkler head operation. Inspection request will be made when ceiling tile is installed and complete.
BLD-Energy code compliance7/20/20177/20/20177/20/2017PPASS
DetailsJim Storey
Brent Phone #: ###-####
BLD-Framing/Rough-in7/17/20177/17/20177/17/2017PPASS
DetailsJim Storey
Brent Phone #: ###-####