Permit Information
Permit NumberBLD17-01764
StatusFinaled
Name SILVER LINING LLC
Site Address 10173 W OVERLAND RD
Project NameWilner & O'Reilly Law Office
Customer Number 
ePlanReviewYes
Description
(WILNER & O’REILLY LAW OFFICE – WHOLE BUILDING TENANT) (DRH15-00284) This building does not have a fire sprinkler system. To construct interior tenant improvements within a 3,531 square foot shell building for an office tenant. This tenant will occupy the entire building. Work is to include two layers of 5/8” Type “X” gypsum board installed as the ceiling membrane of a 1-hr fire-resistance-rated roof-ceiling assembly, a 1-hr attic access hatch, a 1-hr fire-resistance-rated eave and soffit at the East exterior wall, a 1-hr fire-resistance-rated East exterior wall rated for fire exposure from each side, and 1-hr fire-resistance-rated bearing walls (i.e. North, West, and South exterior walls) for fire exposure from the inside. Additional work includes interior nonbearing walls, two toilet rooms accessible to the disabled, interior doors, millwork, and finishes. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final10/9/201710/9/201710/9/2017PPASS
DetailsMike Jordan
Richard Phone #: ###-####. All issues have been resolved.
BLD-Final9/28/20179/29/20179/29/2017APART
DetailsMike Jordan
call for access code - RIchard Phone #: ###-####. Ok for temp occ. Needs to provide listed attic acces doors.
FIRE-Final Inspection9/26/20179/27/20179/27/2017APASS
DetailsTroy Cobbley
life safety passed
BLD-Framing/Rough-in8/15/20178/16/20178/16/2017APASS
DetailsMike Jordan
Richard Phone #: ###-####
BLD-Energy code compliance8/16/20178/16/20178/16/2017APASS
DetailsMike Jordan
Richard Phone #: ###-####
BLD-Framing/Rough-in8/14/20178/15/20178/15/2017APASS
DetailsMike Jordan
Richard Phone #: ###-####
BLD-Framing/Rough-in8/10/20178/11/20178/11/2017PNR
DetailsMike Jordan
Richard Phone #: ###-####
BLD-Framing/Rough-in8/4/20178/9/20178/9/2017AFAIL
DetailsMike Jordan
Richard Phone #: ###-####. Remove all foam from top plate penetrations and provide a UL listed firestop for 1hr. ceiling assembly. All mech openings in 1hr. ceiling assembly will require fire dampers. Need plumbing rough in inspection. No cover at this time. Correction notice issued.