Permit Information
Permit NumberBLD17-02700
StatusFinaled
Name URBAN NUANCE
Site Address 5096 N COLLISTER DR
Project NameUN02
Customer NumberCFH17-00040
ePlanReviewYes
Description
Permit for the construction of a new 1322 sq. ft., one story single family dwelling with 2 bedrooms, 2 bathrooms, approximately 200 sq. ft. of covered patio/porch and a 658 sq. ft. dettached garage per the approved plans, notations, & local code. R-2 zoning and setbacks per planning. **JAB**

A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please allow 24 hours for subgrade approval processing. Call Melissa Jannusch at 208-608-7168

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Melissa Jannusch at 208-608-7168.

An erosion and sediment control site preparation inspection is required for this site. The site preparation inspection takes place after all required erosion and sediment control best management practices have been installed and BEFORE any earthwork takes place. Call 208-608-7070 to schedule an inspection.

Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Conference5/18/20205/18/20205/22/2020PDONE
DetailsTony Young
Screened- Danny Phone #: ###-####
BLD-Final5/19/20205/21/20205/22/2020APASS
DetailsTony Young
Screened- Danny Phone #: ###-####
DOC - Permit Finaled5/22/20205/22/20205/22/2020PPASS
DetailsTony Young
hillside ok from MJ via phone call
BLD-Conference12/9/201912/10/201912/10/2019PPART
DetailsTony Young
Tony.....would like to meet to discuss placement of address for house and ADU 4770 W Hill Rd now 5096 N Collister Dr. ..... Thanks, Danny Phone #: ###-#### Inspection requested via web by Danny Utterbeck// address ?s
BLD-Conference11/8/201911/8/201911/8/2019PPART
DetailsTony Young
Tony! Would like to do a walk through with you for the CO 4770 W Hill Rd
Thanks! Danny Phone #: ###-#### Inspection requested via web by Danny Utterbeck// walk through on final,, needs hillside approval,, address verification,, hill vs. collister,
BLD-Conference8/30/20198/30/20198/30/2019PPEND
DetailsTony Young
needs a mech permit for ADU
BLD-Conference7/9/20197/10/20197/10/2019APART
DetailsTony Young
Tony! Need to visit on a few items of concern! Phone #: ###-#### Inspection requested via web by Danny Utterbeck,,?s on upcoming change to garage upstairs to living,, also noted that garage is not attached
BLD-Framing/Rough-in7/9/20197/10/20197/10/2019APASS
DetailsTony Young
Tony! Need this for Sheetrock cover! Danny please as early as possible! Phone #: ###-#### Inspection requested via web by Danny Utterbeck,, house is ok
BLD-Energy code compliance7/9/20197/10/20197/10/2019APART
DetailsTony Young
Tony! Need this for Sheetrock cover! Danny please as early as possible! Phone #: ###-#### Inspection requested via web by Danny Utterbeck,, house only,, ok
BLD-Framing/Rough-in7/3/20197/5/20197/5/2019PPART
DetailsBrandon Shaw
House only- OK to insulate...
Detached garage and ADU above, to be added to permit and job description- No Inspection at this time...
BLD-Framing/Rough-in7/2/20197/3/20197/3/2019ANR
DetailsTony Young
Tony! I had requested a framing inspection early this morning for this afternoon! Not sure what happened! I have the insulation scheduled for tomorrow and have them on hold now! Thank you! Danny Phone #: ###-#### Inspection requested via web by Danny Utterbeck// need mechanical pass
BLD-Wall Bracing6/11/20196/12/20196/12/2019APASS
DetailsTony Young
Tony, need shear wall inspection for cover up! I’m working on a house close by if you need me! Danny Phone #: ###-#### Inspection requested via web by Danny Utterbeck
BLD-Wall Bracing6/11/20196/11/20196/11/2019PNR
DetailsTony Young
Tony, need shear wall inspection for cover up! I’m working on a house close by if you need me! Danny Phone #: ###-#### Inspection requested via web by Danny Utterbeck
BLD-Aging Inspection5/30/20195/30/20196/3/2019 PASS
DetailsTony Young
BLD-Wall Bracing1/15/20191/15/20191/15/2019PPART
DetailsTony Young
Concrete at 2pm // Adam Phone #: ###-####
foundation wall for garage,, work in progress
BLD-Foundation1/2/20191/2/20191/2/2019PPART
DetailsTony Young
wall- Adam Phone #: ###-####,, house walls ok
BLD-Footing12/12/201812/12/201812/12/2018PPART
DetailsTony Young
Adam Phone #: ###-####-pour time 2:00,, work in progress,, ok,, will protect from cold
BLD-Footing11/27/201811/27/201811/27/2018PNR
DetailsTony Young
Danny ; Phone #: ###-####
BLD-Footing11/26/201811/27/201811/27/2018ANR
DetailsTony Young
Danny ; Phone #: ###-####,, soils ok now,, not ready
BLD-Footing11/20/201811/20/201811/20/2018PNR
DetailsTony Young
Concrete at 3 - Adam Phone #: ###-####