Permit Information
Permit NumberBLD17-02707
StatusIssued
Name EKC INC
Site Address 6434 W GOWEN RD
Project NameVermeer Showroom - West end
Customer Number 
ePlanReviewYes
Description
(VERMEER ROCKY MOUNTAIN – SHOWROOM AND PARTS AREA – WEST WING) (CZC17-00213) The fire sprinkler system is used, perhaps, for the storage and/or repair of commercial vehicles in the East wing. To remodel a portion of the 3,837 square foot West wing of an existing 10,500 square foot building. Most of the work will be within the West wing. Before an interior wall is removed, verification that it is not a bearing wall or a shear wall is required. The existing header at the new double leaf exterior door is required to be maintained. Work is to include accessible upgrades to the existing restrooms, a new wheelchair accessible drinking fountain, a new interior wall infill, new interior nonbearing walls, a parts counter with a portion accessible to the disabled, a new double leaf exterior door, a new exterior concrete landing at that new door, an exterior wall infill of an abandoned doorway, suspended acoustical ceilings, interior finishes, storage racks with storage no higher than 8 feet above the floor, and a new sales counter with a portion accessible to the disabled within the East wing. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. This permit is intended to establish a Certificate of Occupancy for the 3,837 square foot West wing. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/4/20181/5/20181/5/2018APASS
DetailsMike Jordan
Tim Phone #: ###-####. All issues were resolved. Ok for perm occ.
BLD-Final1/2/20181/2/20181/2/2018PNR
DetailsMike Jordan
Tim Phone #: ###-####. Still needs plumbing final.
BLD-Final12/27/201712/27/201712/27/2017PPART
DetailsJim Storey
Tim Phone #: ###-#### need signage and vert bar for ada/ plm and mech permits or removed from signoff by office.
FIRE-Final Inspection12/19/201712/20/201712/20/2017APASS
DetailsTroy Cobbley
Life safety passed

Tim Phone #: ###-####
FIRE-Final Inspection12/18/201712/19/201712/19/2017AFAIL
DetailsJim Page
Called point of contact, Tim Phone #: ###-#### but did not get an answer, FIR permit for fire sprinklers needs to be scheduled and in finaled status before life fire safety inspection can be done.
BLD-Ceiling Grid Inspection11/30/201712/1/201712/1/2017APASS
DetailsMike Jordan
Tim Phone #: ###-####
BLD-Framing/Rough-in11/3/201711/6/201711/6/2017APASS
DetailsBrandon Shaw
Hold downs in place and special inspection report, for welding, on site at time of inspection.

OK to cover
BLD-Framing/Rough-in10/26/201710/26/201710/26/2017PPART
DetailsMike Jordan
20 mins heads up- Tim Phone #: ###-####. Needs special inspection for welding and installation of new holdowns. Interior steel stud framed walls ok. noted existing wall is a shear wall. Also noted new beams and tube steel columns installed per the engineering to pick up roof load of existing load bearing wall that has been demolished.