Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberBLD17-02955
StatusFinaled
Name QUALITY CONSTRUCTION SERVICES
Site Address 2214 E GOODMAN ST
Project NameWarm Springs Apts Bldg B
Customer NumberBLD17-00954 EPLAN
ePlanReview 
Description
(3 PERMITS FILED UNDER BLD17-00954 IN EPLANREVIEW) (WARMS SPRINGS APARTMENTS - BUILDING B) (08/07/18 PLAN MOD TO ADD HOSE BIBB AND DRAIN AT BIKE ENCLOSURE. JAR) (6/20/18 PLAN MODIFICATION TO HVAC DESIGN AND REMOVE EXTERIOR LIGHTS AT FALSE BALCONIES. JAR). (3/23/18 PLAN MODIFICATION TO REVISE ROOF INSULATION AND VENTING AT OVER FRAME ROOF; REMOVE WINDOWS IN STAIRWELLS; REVISE EXTERIOR TRIM. JAR) **Permit for the construction of a 12 unit, 3 story wood framed apartment building with work to include general site work and construction of the new building per the approved plans. This building fire sprinklered with a NFPA-13R system. **JAR**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final8/22/20198/22/20198/22/2019PPASS
DetailsBrandon Shaw
John Phone #: ###-####
DOC - Permit Finaled8/22/20198/22/20198/22/2019PPASS
DetailsBrandon Shaw
BLD-Final8/16/20198/16/20198/19/2019PPEND
DetailsDave Hannah
John Phone #: ###-#### needs returns on handrail
BLD-Conference6/4/20196/4/20196/6/2019PDONE
DetailsDave Hannah
John Phone #: ###-####
BLD-Final6/5/20196/5/20196/5/2019APART
DetailsDave Hannah
ok for tco needs to fix handrail in stair tower
BLD-Final5/30/20195/31/20195/31/2019ANR
DetailsDave Hannah
John Phone #: ###-#### needs four inch lemiters on windows fix handrail in stair tower and opennings in risers
FIRE-Final Inspection4/25/20194/26/20194/26/2019APASS
DetailsJim Page
Fire sprinkler inspection is complete, fire alarm inspection is complete, fire extinguishers are in placed and will be inspected as discussed. Final life fire safety inspection complete.

John Phone #: ###-####
BLD-Other7/20/20187/20/20187/24/2018PPASS
DetailsDave Hannah
John-sheetrock Phone #: ###-####
BLD-Other7/23/20187/24/20187/24/2018APASS
DetailsDave Hannah
energy seal- john Phone #: ###-####
BLD-Other7/23/20187/24/20187/24/2018APASS
DetailsDave Hannah
fire caluking- john Phone #: ###-#### also framing
BLD-Wall Bracing7/19/20187/19/20187/20/2018PPEND
DetailsDave Hannah
John-sheetrock Phone #: ###-####
BLD-Energy code compliance7/18/20187/19/20187/19/2018APASS
DetailsDave Hannah
John Wyman Phone #: ###-####
BLD-Energy code compliance7/13/20187/16/20187/16/2018APASS
DetailsDave Hannah
2nd floor // John Phone #: ###-####
BLD-Energy code compliance7/11/20187/11/20187/12/2018PPASS
DetailsDave Hannah
3rd floor apartment - John Phone #: ###-#### ok to cover
BLD-Other7/9/20187/9/20187/9/2018PPASS
DetailsDave Hannah
fire colk // John Phone #: ###-#### ok to insulate
BLD-Framing/Rough-in7/3/20187/3/20187/3/2018PNR
DetailsDave Hannah
John Phone #: ###-#### framing ok but needs to install firestopping
BLD-Footing6/6/20186/6/20186/6/2018PPASS
DetailsDave Hannah
John Phone #: ###-####-footings for parking lot
BLD-Other4/23/20184/24/20184/24/2018APASS
DetailsDave Hannah
John-Fire wall Phone #: ###-####
BLD-Other4/16/20184/16/20184/17/2018PDONE
DetailsDave Hannah
Fire sheet rock behind showers- Dawn Phone #: ###-#### needs to sheetrock box for valves
BLD-Wall Bracing4/13/20184/13/20184/16/2018PPART
DetailsDave Hannah
John Phone #: ###-#### ok to cover ext
BLD-Footing11/27/201711/27/201711/27/2017PNR
DetailsDave Hannah
John Phone #: ###-####
BLD-Foundation11/8/201711/9/201711/9/2017APASS
DetailsDave Hannah
John-pour time 1:00 Phone #: ###-####
BLD-Footing11/1/201711/2/201711/2/2017APASS
DetailsDave Hannah
John Phone #: ###-####