Permit Information
Permit NumberBLD17-03496
StatusFinaled
Name DEBELLOY CONSTRUCTION
Site Address 6871 W OVERLAND RD
Project NameGyro Shack
Customer Number 
ePlanReviewYes
Description
(GYRO SHACK – REMODEL AND ADDITION) (DRH17-00212) (3-13-18 PLAN MODIFICATION TO REARRANGE THE KITCHEN AREA AND TO MODIFY THE BUFFET LINE. TWO TYPE I GREASE HOOD AND DUCT SYSTEMS WILL BE INSTALLED.) This building does not have a fire sprinkler system. To construct a 27 square foot drive-thru window addition to an existing restaurant building and to remodel the building for a new restaurant tenant. After the addition, this building will have a total interior floor area of about 1,976 square feet. For the addition, work is to include concrete footings, concrete foundation, concrete slab on grade, wood framed exterior walls, exterior windows, a roof with insulation on top of the roof deck and a new membrane roof covering, exterior finishes, and interior finishes. For the existing building, structural work is to include new shear walls; new roof parapets and parapet braces; strengthening existing roof truss to support new roof top equipment, the grease hood, and snow and wind loads caused by the new parapets; and a rebuilt roof structure over the West entry vestibule. Special Inspection is required for concrete and for post installed anchors in hardened concrete. A new trash enclosure will be constructed, a new 12’ x 38’ exterior concrete patio will be placed at the North end of the building, new exterior finishes will be applied, a new awning will be installed above the new drive-thru window, and new exterior doors will be installed in new exterior wall openings. Interior work is to include interior nonbearing walls, two toilet rooms accessible to the disabled, millwork, a Type I grease hood and duct system, kitchen equipment, gypsum board ceilings and soffits, suspended acoustical ceilings, and interior finishes. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/21/20185/21/20185/21/2018PPASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by kevin debelloy. OK for perm occ.
FIRE-Final Inspection5/20/20185/21/20185/21/2018PPASS
DetailsTroy Cobbley
Life safety passed

Phone #: ###-#### Inspection requested via web by kevin debelloy
BLD-Conference5/18/20185/18/20185/18/2018ACANC
DetailsMike Jordan
I might be able to explain my question with a phone a call. ###-#### Phone #: ###-#### >> Inspection requested via web by kevin debelloy Inspection cancelled from web by: kevin debelloy
FIRE-Final Inspection5/17/20185/17/20185/17/2018PFAIL
DetailsTroy Cobbley
Provide occupant load sign, provide testing/annunciator for the duct smoke detector, provide approval of the kitchen hood/appliance layout from the mechanical inspector.

Phone #: ###-#### Inspection requested via web by kevin debelloy
BLD-Energy code compliance4/11/20184/12/20184/12/2018APASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by kevin debelloy.
BLD-Framing/Rough-in4/9/20184/10/20184/10/2018PPASS
DetailsMike Jordan
please call 15 minutes before arrival - thanks Kevin deBelloy Phone #: ###-#### Inspection requested via web by kevin debelloy. Interior steel stud framed walls and steel stud framed walls ok. Structural upgrade work for MAU, new hood and parapets ok.
BLD-Wall Bracing2/19/20182/20/20182/20/2018PPASS
DetailsMike Jordan
inspection is for wall shear on parapet walls Phone #: ###-#### Inspection requested via web by kevin debelloy. Neew parapets.
BLD-Framing/Rough-in2/20/20182/20/20182/20/2018PPASS
DetailsMike Jordan
inspection is for wall shear on parapet walls Phone #: ###-#### Inspection requested via web by kevin debelloy. New parapets ok.
BLD-Energy code compliance1/17/20181/17/20181/17/2018PPASS
DetailsMike Jordan
Inspection is for 2” ridged foundation insulation Phone #: ###-#### Inspection requested via web by kevin debelloy
BLD-Footing1/16/20181/16/20181/16/2018APASS
DetailsMike Jordan
Concrete is scheduled for 10:30 Phone #: ###-#### Inspection requested via web by kevin debelloy. Footing for new drive thru window.