BLD-Final | 9/5/2018 | 9/5/2018 | 9/5/2018 | P | PASS |
Mike Jordan
|
|
|
Please call Justin 1/2-hour prior to inspection, thank you. Phone #: ###-#### Inspection requested via web by Justin Dauby. All issues have been resolved. Ok for perm occ.
|
FIRE-Final Inspection | 9/5/2018 | 9/5/2018 | 9/5/2018 | A | PASS |
Troy Cobbley
|
|
|
Life safety passed.
Please call Justin 1/2-hour prior to inspection, thank you. Phone #: ###-#### Inspection requested via web by Justin Dauby
|
FIRE-Final Inspection | 6/8/2018 | 6/11/2018 | 6/11/2018 | A | PASS |
Troy Cobbley
|
|
|
Life safety passed for the "Lean To" area.
Justin--need 30 mins notice Phone #: ###-####
|
BLD-Final | 4/30/2018 | 5/1/2018 | 5/1/2018 | A | CANC |
Mike Jordan
|
|
|
30mins heads up- Justin Phone #: ###-####
|
BLD-Final | 5/1/2018 | 5/1/2018 | 5/1/2018 | P | PART |
Mike Jordan
|
|
|
ok for temp occ. untill new doors arrive and are installed. Temp. exiting plan ok.
|
FIRE-Final Inspection | 4/30/2018 | 5/1/2018 | 5/1/2018 | A | PART |
Troy Cobbley
|
|
|
A temporary is being given for the life safety until the exiting has been corrected. Plans are currently in review but a temporary exiting plan has been approved and implemented. Need the sidewall sprinkler heads installed when canopy is built.
Justin Phone #: ###-####
|
BLD-Conference | 4/27/2018 | 4/27/2018 | 4/27/2018 | P | DONE |
Mike Jordan
|
|
|
30 mins heads up- Justin Phone #: ###-####
|
FIRE-Conference | 4/27/2018 | 4/27/2018 | 4/27/2018 | P | DONE |
Troy Cobbley
|
|
|
Fire alarm permit needs finaled. The two west exit doors need resolved/approved. Electric doors need to open freely when locked. Provide single action lever hardware on interior doors. Provide the revised approved plans and institute any requirements shown on plans.
30 mins heads up- Justin Phone #: ###-####
|
FIRE-Conference | 3/31/2018 | 4/2/2018 | 4/3/2018 | P | DONE |
Troy Cobbley
|
|
|
I met with Justin and we discussed fire sprinkler issues.
Please call Justin 30-mins to 1-hour in advance, thank you. Phone #: ###-#### Inspection requested via web by Justin Dauby
|
FIRE-Conference | 3/15/2018 | 3/15/2018 | 3/15/2018 | A | DONE |
Troy Cobbley
|
|
|
Justin and I discussed the issue of incorrect pipe sizing in this tenant space as shown on FIR17-00593. The main shown as 4" is actually 3". As per discussion with Scott Arellano the future FIR permit for the dry system (or separate submittal) will need to address this issue with calculations that verify the system does meet minimum code requirments.
Please call Justin 1/2-hour prior to site visit, thank you. Phone #: ###-#### Inspection requested via web by Justin Dauby
|
FIRE-Conference | 3/7/2018 | 3/7/2018 | 3/7/2018 | P | DONE |
Troy Cobbley
|
|
|
We went over sprinkler issues such as the coverage under the stair and at the entry vestible. We discussed the west side exiting that is being resubmitted and per the review comments a manual fire alarm system is required as per the review comments.
30 mins heads up- Justin Phone #: ###-####
|
FIRE-Conference | 2/28/2018 | 3/1/2018 | 3/1/2018 | A | DONE |
Troy Cobbley
|
|
|
We went over issues with lack of sprinkler coverage which was agreed to be taken care of with the vanilla finish permit and the need for a possible plan modification for the west exit/canopy exiting system.
|