Permit Information
Permit NumberBLD17-04274
StatusFinaled
Name RRC CONTRACTORS
Site Address 7609 W OVERLAND RD
Project NameChow Public Market
Customer Number 
ePlanReviewNo
Description
(CHOW PUBLIC MARKET – BOISE SPECTRUM – BUILDING C) **This building is fire sprinklered for building area increase and fire area. Permit to combine units 130, 140, 150, 160 to create a 7,200 sq ft open food court with 4 associated kitchen areas and retail sales area. Work to include: new interior nonbearing partitions; new exterior windows and overhead doors; relocated doors; new commercial kitchens; new plumbing, electrical, and mechanical; and new finishes to be in compliance with Ch. 8 of the 2012 IBC. Work is required to comply with the approved drawings, plan review report, and with all applicable codes and ordinances. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JAR**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/19/20186/20/20186/20/2018APASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Don Walker. Ok for temp occ. Will be ok for perm occ. once electrical signs perm.
FIRE-Final Inspection6/19/20186/20/20186/20/2018APASS
DetailsTroy Cobbley
life safety passed

Don Phone #: ###-####
BLD-Final6/13/20186/14/20186/14/2018ACANC
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Don Walker
BLD-Conference6/14/20186/14/20186/14/2018ADONE
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Don Walker. Walk through prior to final. Needs to provide ADA portion of counter top at wine bar. Provide ADA bathroom signs.
FIRE-Final Inspection6/13/20186/14/20186/14/2018AFAIL
DetailsTroy Cobbley
Provide exit discharge lights per the approved plans. Mount the two fire extinguishers in the DIning Area and provide an additional one in the back corridor. Provide the two occupant load signs.

Phone #: ###-#### Inspection requested via web by Don Walker
FIRE-Conference5/23/20185/23/20185/23/2018PDONE
DetailsTroy Cobbley
The project superintendant and I went over the door hardware requirements and exit path requirements.
BLD-Ceiling Grid Inspection4/17/20184/18/20184/18/2018PPASS
DetailsMike Jordan
Please call when headed our way. Phone #: ###-#### Inspection requested via web by Don Walker
BLD-Ceiling Grid Inspection3/22/20183/22/20183/22/2018PPART
DetailsBrandon Shaw
Inspection in hard lid ares in bathrooms, retail 1 and retail 2- OK to cover
BLD-Wall cover3/6/20183/7/20183/7/2018ACANC
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Don Walker
BLD-Framing/Rough-in3/7/20183/7/20183/7/2018APASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Don Walker. Interior steel stud framed walls and soffits only.