Permit Information
Permit NumberBLD17-04297
StatusFinaled
Name DATUM CONSTRUCTION MANAGEMENT INC
Site Address 10477 W FAIRVIEW AVE
Project NameBelmont Plaza Facade
Customer Number 
ePlanReviewYes
Description
(BELMONT PLAZA FACADE) **The fire sprinkler system is used for unlimited area of the building AND to allow 3-hr fire barrier walls in lieu of fire walls. The fire sprinkler system is NOT allowed to be used for building area increase for A Occupancies. This façade addition is not required to be sprinklered. The canopies will comply with NFPA 13-8.15.1.2.2 as noncombustible concealed spaces. No combustible materials can be stored or displayed underneath the façade addition. Permit for upgrades to the facade. Work to include the demolition of exterior signage canopy/awning and sidewalk; new sidewalk; installation of new exterior finishes to include new stucco on metal studs built over the existing CMU exterior bearing wall, which is to remain, and new awnings. Special Inspections required per attached form 310. The work is required to comply with the approved drawings, with the structural design, and with all applicable codes and ordinances. This permit is for shell work only. This permit is not intended to establish a Certificate of Occupancy for any tenant or for any portion of this building. Each tenant is required to apply for their own permit to do tenant improvement work and to establish occupancy. **JAR**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/4/20185/4/20185/4/2018PPASS
DetailsMike Jordan
Cody Phone #: ###-####
DOC - Permit Finaled5/4/20185/4/20185/4/2018PPASS
DetailsMike Jordan
FIRE-Final Inspection5/3/20185/4/20185/3/2018APASS
DetailsTroy Cobbley
Life safety passed. Per verbal agreement the existing red fire lane painting will be extended to the west end of the building complex next week when stripping occurs.

Cody Phone #: ###-####
BLD-Framing/Rough-in3/8/20183/9/20183/9/2018APASS
DetailsMike Jordan
Cody-partial Phone #: ###-####
BLD-Framing/Rough-in2/23/20182/26/20182/26/2018APASS
DetailsMike Jordan
Partial/conference - Cody Phone #: ###-####. Exterior steel stud framing for ne facade at dead on archery main enterance, and remaining facade on north west corner of building.
BLD-Framing/Rough-in2/16/20182/16/20182/20/2018PPASS
DetailsDave Hannah
Cody Phone #: ###-####
FIRE-Conference2/16/20182/16/20182/16/2018PDONE
DetailsTroy Cobbley
Conference was to discuss whether fire sprinkler protection would be required in the new canopy. Per the fire review comments none are required with conditions

Cody Phone #: ###-####
BLD-Framing/Rough-in2/13/20182/13/20182/13/2018PPASS
DetailsMike Jordan
Bays 3 and 4 ok.
BLD-Framing/Rough-in2/7/20182/7/20182/7/2018PPASS
DetailsMike Jordan
Cody-partial-infront of the Ace Hardware Phone #: ###-####. Exterior steel stud framing for new facade at bays 5 and 6.
BLD-Framing/Rough-in1/31/20181/31/20181/31/2018PPASS
DetailsMike Jordan
Egor-Partial framing Phone #: ###-####. Exterior steel stud framed walls and for canopys and columns for new facade on space A and B.
BLD-Framing/Rough-in1/24/20181/25/20181/25/2018APASS
DetailsMike Jordan
Igor Phone #: ###-####. Bays 1 to 5 exterior flutting cover with steel studs ok. ok to cover with the 1/2 inch fire rated ply wood.