Permit Information
Permit NumberBLD17-04365
StatusIssued
Name ASC
Site Address 1404 W JEFFERSON ST
Project NameCity Light Home - Bathroom Rem
Customer Number 
ePlanReviewYes
Description
(CITY LIGHT HOME) Remodel existing basement bathrooms to encompass additional showers and fixtures. Provide new finishes and modify existing HVAC and Plumbing. This building is fully fire sprinklered with an approved fire alarm system. Separate permits will be required by the necessary modifications to the building fire protection systems; as regulated by Boise Fire Department. RmH
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Aging Inspection3/13/20193/13/20193/13/2019 PEND
DetailsTony Young
BLD-Aging Inspection3/12/20193/12/20193/13/2019 FAIL
DetailsTony Young
FIRE-Final Inspection10/29/201810/29/201810/29/2018PFAIL
DetailsJim Page
City approved drawings and small documentation not on site, city approved drawings and associated small documents are required for the inspection process. Performed courtesy inspection for basic life safety items, no emergency lighting in shower/restroom area. Fire alarm modifications are required for area of work as noted in the fire conference notes entered in on 9JULY2018 under this BLD permit.

Fire alarm panel was showing a trouble at time of inspection, fire alarm panel needs to show a normal panel before life fire safety inspection.

John or ###-#### Breanna Phone #: ###-####
BLD-Final10/22/201810/23/201810/23/2018ANR
DetailsTony Young
Terry Weymouth Phone #: ###-####,, needs f/l/s 1st,, no inspection made
BLD-Framing/Rough-in7/9/20187/10/20187/10/2018APASS
DetailsTony Young
Terry Phone #: ###-####-please call 1 hr prior to meet,, ok pending trades
FIRE-Conference7/9/20187/9/20187/9/2018ADONE
DetailsJim Page
Performed a rough in inspection for overhead fire sprinkler piping in remodeled area on the basement level, fire alarm modifications will be required (Fire alarm devices are hanging by the conduit that is attached to devices and as of 09JULY2018 there is no new permit in the PDS system for fire alarm modifications associated with this project). Fire alarm modifications will be required to be completed before life fire safety inspection. Also the property address has an outstanding permit for past fire alarm work, permit number is FIR14-00490. FIR14-00490 permit will be required to be finaled, no finals for the new fire alarm work or life fire safety will be signed off until FIR14-00490 is inspected and finaled.
BLD-Framing/Rough-in6/4/20186/5/20186/5/2018APART
DetailsTony Young
Art Phone #: ###-####,, needs trades,, sprinklers,, fireblocking,, etc.. walk through only