Permit Information
Permit NumberBLD17-04479
StatusFinaled
Name BARKER CONTRACTING INC
Site Address 3419 N COLE RD
Project NameCSL Plasma
Customer NumberBLD18-00076 NONSTRUCT DEMO
ePlanReviewNo
Description
(CSL PLASMA – BLOOD PLASMA COLLECTION FACILITY) (CZC17-00210) The fire sprinkler system is used for building area increase and for fire area. Interior nonstructural demolition work was done under permit BLD18-00076. To completely renovate a 11,653 square foot tenant space for a blood plasma collection facility where no one will be incapable of self-preservation. Work is to include a 400 square foot recessed concrete slab on grade to accommodate the floor thickness of a new walk-in freezer; concrete floor patches at plumbing trenches; concrete footings, steel columns, and a steel beam to redirect roof gravity loads where a column will be removed; structural upgrades to the roof structure to support new roof top HVAC units; exterior concrete landings, ramps, rails, and awnings at the back exterior doors; new concrete stem walls where existing exterior doors will be removed in the storefront; interior nonbearing walls; suspended acoustical ceilings; gypsum board soffits and bulkheads; 2 multi-user toilet rooms accessible to the disabled for the public; 2 multi-user toilet rooms accessible to the disabled for employees; interior windows; interior doors; double-acting gates; service counters; new storefront doors and windows; millwork; equipment; furniture, and interior finishes. Special Inspection is required for soils, concrete, masonry, welding, and epoxy anchors and other anchors post-installed in hardened concrete. The West awnings are allowed to be deferred submittal items. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 (including quick-response heads installed in light-hazard areas) and the partial fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/6/20186/7/20186/7/2018PPASS
DetailsJim Sly
Dave Phone #: ###-####
OK for Perm Occ.
FIRE-Final Inspection6/6/20186/7/20186/7/2018APASS
DetailsTroy Cobbley
life safety passed

Dave Phone #: ###-####
BLD-Final6/5/20186/6/20186/6/2018PNR
DetailsJim Sly
Dave Barker Phone #: ###-####
Need FIR18-00379 Final.
FIRE-Final Inspection6/5/20186/6/20186/6/2018AFAIL
DetailsTroy Cobbley
Life safety will be ok to pass when the two emergency lights are repaired and the project related fire alrm permit is finaled.

Dave Barker Phone #: ###-####
BLD-Final6/1/20186/1/20186/1/2018PNR
DetailsJim Sly
Dave Phone #: ###-####
Need all fire finals and MEC 18-00890
FIRE-Final Inspection6/1/20186/1/20186/1/2018PFAIL
DetailsTroy Cobbley
Need sign offs on the project related fire alarm and fire sprinkler permits. Need the three missing exit discharge lights installed and tested. Need the emergency lights marked on the city approved plans repaired and tesed

Dave Phone #: 208-###-####
BLD-Ceiling Grid Inspection5/17/20185/17/20185/17/2018PPASS
DetailsJim Sly
Dave Phone #: ###-####
BLD-Framing/Rough-in5/3/20185/3/20185/4/2018PPASS
DetailsJim Sly
Dave Phone #: ###-####
BLD-Framing/Rough-in3/19/20183/19/20183/19/2018PPASS
DetailsJim Sly
Dave Phone #: ###-####
BLD-Framing/Rough-in3/12/20183/13/20183/13/2018APART
DetailsJim Sly
Dave-partial-room #er''s-rooms 137, 143, 144, 134, 133, 110, 141, 142, 107, 104, 102 north wall Phone #: ###-####
BLD-Concrete3/1/20183/2/20183/2/2018APASS
DetailsJim Sly
pouring at 9am- Dave Phone #: ###-####
BLD-Concrete3/1/20183/1/20183/2/2018PDONE
DetailsJim Sly
Dave Phone #: ###-####
BLD-Foundation2/27/20182/27/20182/27/2018PCANC
DetailsJim Sly
Stem wall for garage - Jeremy Phone #: ###-####
BLD-Conference2/27/20182/27/20182/27/2018PDONE
DetailsJim Sly
Please call if after 3:30 - Dave Phone #: ###-####