(LYLE PEARSON VOLVO – WEST BUILDING ADDITION) (DRH17-00566) (1-15-19 PLAN MODIFICATION TO REPLACE THE FORMERLY PROPOSED EXTERIOR AUTOMOBILE DOOR LEAVES INCLUDING THE ADJACENT SIDE-HINGED EXIT DOOR AT THE AUTOMOBILE SHOW ROOM WITH AN OVERHEAD DOOR. THE OCCUPANT LOAD OF THE SHOW ROOM WAS RE-EVALUATED AND THE OCCUPANT LOAD WAS DETERMINED TO BE 47 AND THE MAXIMUM TRAVEL DISTANCE TO THE OUTSIDE WAS DETERMINED TO BE LESS THAN 100 FEET LONG REQUIRING ONLY ONE EXIT.) (9-6-18 PLAN MODIFICATION TO REVISE THE SITE GRADING AND DRAINAGE AND TO DELETE A LANDSCAPE PLANTER AND TO MODIFY ANOTHER LANDSCAPE PLANTER.) The fire sprinkler system is used for building area increase, story increase, and for fire area. To construct a 5,249 square foot 1st story addition to the existing 17,286 square foot 1st story of an existing two story building (4,943 square foot existing 2nd story). After the addition, the 1st story will have a total floor area of about 22,535 square feet. Work is to include concrete footings, concrete stem walls, concrete slabs on grade, exterior and interior masonry bearing walls, exterior and interior steel stud bearing and shear walls with OSB sheathing, steel beams and steel columns, steel headers and epoxy bolts at new masonry wall openings, steel bar roof joists, steel roof deck, minimum R-30 rigid insulation installed on top of the roof deck, a single ply roofing membrane, aluminum composite exterior panels, exterior windows, exterior doors, interior nonbearing walls, a toilet room accessible to the disabled, interior glass windows/walls, interior doors, ribbed wood suspended ceiling, suspended acoustical ceiling, gypsum board ceilings and soffits, millwork, and finishes. Special Inspection is required for concrete, masonry, steel (welding), and anchors (rebar, bolts, etc.) post-installed in masonry or hardened concrete. The entry portal, including its structural design, is a deferred submittal item. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. This permit is intended to establish a Certificate of Occupancy only for the 5,249 square foot 1st story addition. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
|