Permit Information
Permit NumberBLD17-04568
StatusFinaled
Name THE RUSSELL CORPORATION
Site Address 7805 W GRATZ DR
Project NameLyle Pearson Volvo - Addition
Customer Number 
ePlanReviewYes
Description
(LYLE PEARSON VOLVO – WEST BUILDING ADDITION) (DRH17-00566) (1-15-19 PLAN MODIFICATION TO REPLACE THE FORMERLY PROPOSED EXTERIOR AUTOMOBILE DOOR LEAVES INCLUDING THE ADJACENT SIDE-HINGED EXIT DOOR AT THE AUTOMOBILE SHOW ROOM WITH AN OVERHEAD DOOR. THE OCCUPANT LOAD OF THE SHOW ROOM WAS RE-EVALUATED AND THE OCCUPANT LOAD WAS DETERMINED TO BE 47 AND THE MAXIMUM TRAVEL DISTANCE TO THE OUTSIDE WAS DETERMINED TO BE LESS THAN 100 FEET LONG REQUIRING ONLY ONE EXIT.) (9-6-18 PLAN MODIFICATION TO REVISE THE SITE GRADING AND DRAINAGE AND TO DELETE A LANDSCAPE PLANTER AND TO MODIFY ANOTHER LANDSCAPE PLANTER.) The fire sprinkler system is used for building area increase, story increase, and for fire area. To construct a 5,249 square foot 1st story addition to the existing 17,286 square foot 1st story of an existing two story building (4,943 square foot existing 2nd story). After the addition, the 1st story will have a total floor area of about 22,535 square feet. Work is to include concrete footings, concrete stem walls, concrete slabs on grade, exterior and interior masonry bearing walls, exterior and interior steel stud bearing and shear walls with OSB sheathing, steel beams and steel columns, steel headers and epoxy bolts at new masonry wall openings, steel bar roof joists, steel roof deck, minimum R-30 rigid insulation installed on top of the roof deck, a single ply roofing membrane, aluminum composite exterior panels, exterior windows, exterior doors, interior nonbearing walls, a toilet room accessible to the disabled, interior glass windows/walls, interior doors, ribbed wood suspended ceiling, suspended acoustical ceiling, gypsum board ceilings and soffits, millwork, and finishes. Special Inspection is required for concrete, masonry, steel (welding), and anchors (rebar, bolts, etc.) post-installed in masonry or hardened concrete. The entry portal, including its structural design, is a deferred submittal item. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. This permit is intended to establish a Certificate of Occupancy only for the 5,249 square foot 1st story addition. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/24/20195/28/20195/28/2019APASS
DetailsMike Jordan
Call when you head this way. Phone #: ###-#### Inspection requested via web by Bob Thornton. All issues resolved. OK for perm occ.
BLD-Final5/10/20195/10/20195/10/2019PCANC
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Bob Thornton Inspection cancelled from web by: Bob Thornton
BLD-Final4/12/20194/15/20194/15/2019APART
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Bob Thornton. OK for temp occ. Needs to provide ADA compliant sales counter in lobby. Provide final letter from special inspection firm.
BLD-Final4/12/20194/12/20194/12/2019PNR
DetailsMike Jordan
Please call me when you head this way. Phone #: ###-#### Inspection requested via web by Bob Thornton
FIRE-Final Inspection3/27/20193/28/20193/28/2019APASS
DetailsTroy Cobbley
Life safety passed

Phone #: ###-#### Inspection requested via web by Bob Thornton
BLD-Conference3/19/20193/19/20193/19/2019PDONE
DetailsMike Jordan
Give me a call Phone #: ###-#### Inspection requested via web by Bob Thornton
FIRE-Final Inspection3/18/20193/19/20193/19/2019AFAIL
DetailsTroy Cobbley
Need project related fire alarm permit finaled, another fire alarm permit needs to be applied for due to an apparent fire alarm panel replacement, need one additional fire extinguisher in the Shop, need thumbturn deadbolts removed as discussed.

I''ll plan to walk with you when you finish the alarm inspection. Phone #: ###-#### Inspection requested via web by Bob Thornton
BLD-Ceiling Grid Inspection1/14/20191/15/20191/15/2019APASS
DetailsMike Jordan
Bob Phone #: ###-####
BLD-Ceiling Grid Inspection1/10/20191/11/20191/11/2019ACANC
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Bob Thornton
BLD-Ceiling Grid Inspection1/3/20191/3/20191/3/2019PPASS
DetailsMike Jordan
Call when you are headed this way. Phone #: ###-#### Inspection requested via web by Bob Thornton. Upper ceiling grid ok.
BLD-Conference12/27/201812/27/201812/27/2018PDONE
DetailsBrandon Shaw
Drop ceiling grid to be installed as per Manufactures installations instructions...
BLD-Ceiling Grid Inspection11/15/201811/16/201811/16/2018PPASS
DetailsJim Sly
Please look at the hard lid areas. Phone #: ###-#### Inspection requested via web by Bob Thornton
BLD-Energy code compliance10/31/201810/31/201810/31/2018PPASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Bob Thornton
BLD-Framing/Rough-in10/22/201810/22/201810/22/2018PPASS
DetailsMike Jordan
The inspection letter from the engineer is in my office. Phone #: ###-#### Inspection requested via web by Bob Thornton. Recieved letter from enginner of record. Ok to insulate.
BLD-Framing/Rough-in10/17/201810/18/201810/18/2018APART
DetailsMike Jordan
Bob Phone #: ###-####. Interior steel stud framed walls and soffits ok. Engineer of record to review exterior shear wall construction and approve or with modification.
BLD-Footing8/2/20188/2/20188/2/2018PPART
DetailsMike Jordan
Look at thickened footing in the show room. Concrete tomorrow morning. Phone #: ###-#### Inspection requested via web by Bob Thornton. Will have special ispection.
BLD-Foundation6/12/20186/13/20186/13/2018APART
DetailsMike Jordan
Late morning would be good. We have concrete scheduled for 1:00 Phone #: ###-#### Inspection requested via web by Bob Thornton. work in progress. Will have special inspection.
BLD-Footing6/6/20186/7/20186/8/2018PPASS
DetailsMike Jordan
We will be ready late afternoon. Phone #: ###-#### Inspection requested via web by Bob Thornton