Information based on query as of Monday, May 20, 2024.
Permit Information
Permit NumberBLD17-04623
StatusFinaled
Name RTA SKYLINE LLC
Site Address 2180 S HUDSON AVE
Project NameSkyline Apartments Bldg A
Customer NumberBLD17-04623 TO BLD17-04632
ePlanReviewYes
Description
(Building A)(SKYLINE APARTMENTS – BUILDING TYPE 2, Building A, B, C, E, G and J) (24 units)PLAN MOD RELOCATE WAHER/DRYER FROM BATHROOM TO HALLWAY ADD CLOSED DOOR AS NOTED ON APPROVED PLANS 7-2-18**AJS**The NFPA 13-R fire sprinkler system is used for occupancy and for story increase. To construct a 25,320 square foot three story VB Type of Construction apartment building (8,458 sq. ft. 1st story and 8,431 sq. ft. 2nd story and 8,431 sq. ft. 3rd story). Each unit is 1 story. Work is to include concrete footings, concrete foundations, concrete slabs on grade, wood stud bearing walls, wood stud shear walls, fiberglass shingles, 1-hr dwelling unit separations, 1 hour fire barriers for stair and breezeways, rated doors in breezeway, interior nonbearing walls, millwork, and finishes. Special Inspection is NOT required. The roof truss design is a deferred submittal item. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13-R as regulated by the Fire Department. Separate fire sprinkler permits shall be obtained prior to beginning any modification or installation work on such systems. **ajs**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final10/22/201910/23/201910/23/2019APASS
DetailsJim Storey
BLD-Aging Inspection9/2/20199/2/20199/3/2019 PASS
DetailsJim Storey
ramp ok
BLD-Final7/3/20197/3/20197/5/2019PPART
DetailsJim Storey
building final Phone #: ###-#### Inspection requested via web by J.C. Murray temp ok pending c/n for ramp 1014.4 and pz perm.
BLD-Final7/2/20197/3/20197/3/2019ANR
DetailsJim Storey
building final Phone #: ###-#### Inspection requested via web by J.C. Murray
BLD-Final7/2/20197/2/20197/2/2019PDEFR
DetailsJim Storey
building final Phone #: ###-#### Inspection requested via web by J.C. Murray am 7/3
FIRE-Final Inspection7/2/20197/2/20197/2/2019PPASS
DetailsJim Page
Previously noted items have been corrected, fire sprinkler inspection is complete, fire alarm inspection is complete, fire extinguishers are placed with current inspection tags, final life fire safety inspection complete.

fire/ life ; safety final Phone #: ###-#### Inspection requested via web by J.C. Murray
BLD-Final6/25/20196/26/20196/26/2019PCANC
DetailsJim Storey
Final occupancy signature. Phone #: ###-#### Inspection requested via web by J.C. Murray
FIRE-Final Inspection6/25/20196/26/20196/26/2019PFAIL
DetailsJim Page
Called point of contact with no answer, provide street address fopr building. Could not access rooms to verify sprinkler escutcheons were in place. Need fire lane signage installed where required.

Fire/ Life ; Safety Final. Phone #: ###-#### Inspection requested via web by J.C. Murray
BLD-Aging Inspection6/11/20196/11/20196/11/2019 PASS
DetailsJim Storey
FIRE-Conference3/29/20193/29/20193/29/2019PDONE
DetailsJim Page
Each building that is requiring heat trace on the fire sprinkler lines has a FIR permit associated with the heat trace install. Inspection for heat trace needs to be scheduled with the associated permit for proper inspection procedure.

Breezeway sprinkler pipe heat tape insulation inspection
for Buildings A B C E. Phone #: ###-#### Inspection requested via web by J.C. Murray
BLD-Ceiling Grid Inspection3/7/20193/8/20193/8/2019PPASS
DetailsJim Storey
Builiding A - drop ceiling for cover, fire caulking. Phone #: ###-#### Inspection requested via web by J.C. Murray lower units fed side
BLD-Ceiling Grid Inspection3/4/20193/4/20193/4/2019PPASS
DetailsJim Storey
Bld A - north 12 units. drop ceilings for cover. fire caulking Phone #: ###-#### Inspection requested via web by J.C. Murray
BLD-Energy code compliance1/28/20191/28/20191/28/2019PPASS
DetailsJim Storey
Bld A - insulation energy code. RC channel at ceilings and walls. Phone #: ###-#### Inspection requested via web by J.C. Murray
BLD-Other1/22/20191/23/20191/23/2019APASS
DetailsJim Storey
building A - interior framing and fire caulking. Phone #: ###-#### Inspection requested via web by J.C. Murray
BLD-Framing/Rough-in1/18/20191/22/20191/22/2019PDEFR
DetailsJim Storey
building A - interior framing and fire caulking. Phone #: ###-#### Inspection requested via web by J.C. Murray
BLD-Framing/Rough-in11/27/201811/28/201811/28/2018PPASS
DetailsJim Storey
exterior railing and straps, interior first floor hold-downs and tighten bolts and truss engineering // JC Phone #: ###-####
BLD-Framing/Rough-in11/26/201811/27/201811/27/2018PNR
DetailsJim Storey
exterior railing and straps, interior first floor hold-downs and tighten bolts and truss engineering // JC Phone #: ###-####
BLD-Wall Bracing9/20/20189/21/20189/21/2018APART
DetailsBrandon Shaw
Interior shear, first floor
BLD-Framing/Rough-in9/20/20189/21/20189/21/2018ACANC
DetailsBrandon Shaw
JC Phone #: ###-####
BLD-Foundation7/19/20187/20/20187/20/2018APASS
DetailsJim Storey
wall- Manuel Phone #: ###-####
BLD-Foundation7/19/20187/19/20187/19/2018PDEFR
DetailsJim Storey
wall- Manuel Phone #: ###-####out of time
BLD-Footing7/16/20187/17/20187/17/2018APASS
DetailsJim Storey
manny Phone #: ###-####