Permit for the construction of a new 1,811 sq. ft., two story (first story 897 sq. ft., second story 914 sq. ft.) single family dwelling with 3 bedrooms, 2 and a half bathrooms, approximately 38 sq. ft. of covered patio/porch and a 492 sq. ft. attached garage per the approved plans and any notations. Prescriptive Energy Compliance. R-1C zoning and setbacks per planning. ***RDP***
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final11/19/201811/20/201811/20/2018APASS
DetailsJim Sly
code for garage code- Shawn Phone #: ###-####
Blower door.......3.7
DOC - Permit Finaled11/20/201811/20/201811/20/2018PPASS
DetailsJim Sly
BLD-Conference10/3/201810/3/201810/3/2018PDONE
DetailsJim Sly
per Jim Sly-call neighbor Melissa when on way to conference with GC ###-####
BLD-Conference9/27/20189/28/20189/28/2018ACANC
DetailsJim Sly
neighbor has concerns that the retaining wall is not done correctly or to code-can you please check on it
Could not meet with owner-
BLD-Energy code compliance7/18/20187/19/20187/19/2018APASS
DetailsJim Sly
Shawn Phone #: ###-####
BLD-Framing/Rough-in7/18/20187/19/20187/19/2018APASS
DetailsJim Sly
Shawn Phone #: ###-####
BLD-Framing/Rough-in7/13/20187/16/20187/16/2018AFAIL
DetailsMike Jordan
Shawn Phone #: ###-####. Nail off simpson hangars in garage. Provide tempered glazing at window bottom of stairs. Fire block flue cahse 2nd floor ceiling. fireblock 1st floor ceiling at mech chase. Aslo had contractor remove portions of tyvek to spot check wall bracing and verified all blocking. Correction notice posted. Ok to insulate.
BLD-Conference5/25/20185/29/20185/29/2018ADONE
DetailsJim Sly
Check back to see if string pulled.
Contractor pulled line on East side of house. Fondation wall at 5' 1 1/4 " from property line.....OK.
BLD-Conference5/24/20185/24/20185/25/2018PPEND
DetailsJim Sly
complaint please verify setbacks. Says foundations for 4208 & 4212 Teton are closer than 5' to property line.
Called Contractor. Told him to Pull string line on East side. as of 5/25 2:40 PM not done yet. Will check on Tues.
BLD-Foundation5/22/20185/23/20185/23/2018PPASS
DetailsJim Sly
Phone #: 2086971241 >> Inspection requested via mobile web by Heron lira
BLD-Footing5/21/20185/22/20185/23/2018PPASS
DetailsJim Sly
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo Lira