Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberBLD18-01251
StatusFinaled
Name HUNTER HOMES INC
Site Address 4125 W GARNET ST
Project Name 
Customer Number 
ePlanReviewNo
Description
**ROUTE TO FIRE REVIEW** Structure must be Fully Sprinkled. Permit for the construction of a new 2317 sq. ft., two story (first story 1253 sq. ft., second story 1064 sq. ft.) single family dwelling with 4 bedrooms, 2.5 bathrooms, approximately 70 sq. ft. of covered patio/porch and a 735 sq. ft. attached garage per the approved plans and any notations. Prescriptive Energy Compliance. R-2 zoning and setbacks per planning. ***RDP***

Fire Code Review
Fire sprinklers ARE required due to access issues (flag lot). As alternative, the driveway shall be a minimum of 20’ wide and capable of supporting 75,000 pounds. In addition, the fire apparatus will not pull in more than 150’, at that point all portions of the dwelling shall be within 150’ (middle of the back of the dwelling.)
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final10/26/201810/29/201810/29/2018APASS
DetailsMike Jordan
Call for access // David Phone #: ###-####
DOC - Permit Finaled10/29/201810/29/201810/29/2018PPASS
DetailsMike Jordan
BLD-Final10/25/201810/26/201810/26/2018APART
DetailsTony Young
Call for access // David Phone #: ###-####,, ok,, just needs address facing Garnet st. , seal exterior siding at pipes/ wires,, c of o issued
BLD-Energy code compliance8/30/20188/30/20188/31/2018PPASS
DetailsTony Young
DAve Phone #: ###-####
BLD-Framing/Rough-in8/30/20188/30/20188/30/2018PPASS
DetailsTony Young
DAve Phone #: ###-####
BLD-Framing/Rough-in8/22/20188/23/20188/23/2018AFAIL
DetailsMike Jordan
Steve Phone #: ###-####. Provide truss enginering. Fireblock HVAC chase at cieling first floor. Roll block 2nd floor floor joist At mid bearing. Will need a tenting inspection on fire spinklers prior to energy code inspection. Ok to insulate. Correction notice posted.
BLD-Framing/Rough-in8/15/20188/15/20188/15/2018PNR
DetailsTony Young
David Phone #: ###-####,, needs fire sprinklers passed 1st
BLD-Wall Bracing7/13/20187/13/20187/13/2018PPASS
DetailsTony Young
Kevin Phone #: ###-####,, ok after fixes
BLD-Foundation6/12/20186/13/20186/13/2018PPASS
DetailsTony Young
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo Lira
BLD-Footing6/11/20186/12/20186/12/2018PPASS
DetailsDave Hannah
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo Lira
BLD-Footing6/4/20186/5/20186/5/2018PNR
DetailsTony Young
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo Lira