Permit NumberBLD18-01631
StatusFinaled
Name Carrie Carter
Site Address 1410 N ETHRIDGE LN
Project NameBoise Daycare
Customer Number 
ePlanReviewYes
Description
(BOISE DAYCARE – FORMER GIRL SCOUTS BUILDING) (CUP17-00095) (2-6-19 PLAN MODIFICATION TO ADD MORE PARKING SPACES AND TO CHANGE THE CONFIGURATION OF THE EXTERIOR FENCED CHILD PLAY AREA; IN THE BASEMENT TO ADD A WASHER AND A DRYER TO THE MECHANICAL ROOM, ADD A BASE CABINET IN THE MULTI-PURPOSE ROOM, REMOVE A TOILET FROM AN EXISTING NON-ACCESSIBLE TOILET ROOM, AND TO REVISE THE FOOD PREPARATION AREA TO INCLUDE BASE CABINETS, A HAND SINK, A 3 BASIN SINK, A DISHWASHER, A RANGE, AND A MICROWAVE OVEN; ON THE GRADE LEVEL TO CONSTRUCT A LOW HEIGHT WALL, ADD ACCESSIBLE SINKS, AND TO ADD BASE CABINETS IN CHILD CARE ROOMS; ON THE UPPER LEVEL TO REVISE THE LAYOUT OF THE NEW TOILET ROOM AND TO ADD A BOAT SHAPED RAISED PLATFORM PLAY STRUCTURE IN A CHILD CARE ROOM.) The fire sprinkler system is used for code trade-offs (e.g. in lieu of rated corridors, to allow closer exit separation, and to allow an E Occupancy in the basement). A fire sprinkler system and a horn/strobe type fire alarm system are required to be installed throughout this building under separate permits. To remodel an existing 6,813 square foot building (4,703 square foot 1st story and 2,110 square foot basement) for a new daycare tenant. The 4,703 square foot 1st story has a 3,201 square foot lower level at grade and a 1,502 square foot upper level. Work is to include a new exterior door, interior nonbearing walls, a toilet room accessible to the disabled, a “high” and “low” drinking fountain accessible to the disabled, upgraded guards, upgraded handrails, panic hardware, and finishes. A 3,300 square foot fenced play area will also be created. A code compliant egress system is required from the fenced play area. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. Children less than 2.5 years of age are allowed to be cared for only within rooms having a door directly to the outside. Smoke alarms are required in rooms used for sleeping. Carbon monoxide detectors are required within this building if fuel burning appliances are provided within this building. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final10/29/201910/30/201910/30/2019APASS
DetailsMike Jordan
Carrie Phone #: ###-####. Ok for perm occ. Also verified that the pad lock has been removed from the east gate.
FIRE-Final Inspection10/15/201910/16/201910/16/2019PPASS
DetailsTroy Cobbley
Life safety passed. Carrie is to remove the padlock on the east side gate in the fence that the basement and second floor empty into. Carrie Phone #: ###-####
BLD-Conference8/13/20198/19/20198/19/2019ADONE
DetailsMike Jordan
Call ahead to meet // Kerry Phone #: ###-####. Walk through. Noted no inspections for exterior door and new wall.
FIRE-Conference7/25/20197/25/20197/25/2019PDONE
DetailsTroy Cobbley
Carrie and I went over her life safety comments
BLD-Conference11/21/201811/26/201811/26/2018ADONE
DetailsMike Jordan
Louie Phone #: ###-####. Call before going out.. Needs to call public works to discuss the gutter. Also suggested to contractor to contact fire inspector for conferance on fire alarm requirements.
BLD-Conference11/21/201811/21/201811/21/2018PCANC
DetailsMike Jordan
Louie Phone #: ###-####. Rescheduled for Monday 11-26 in the am.