Permit Information
Permit NumberBLD18-02141
StatusFinaled
Name CANYON CREST HOMES
Site Address 1699 N MOCKBEE PL
Project Name5-1 Sherman Hollow
Customer Number 
ePlanReviewYes
Description
FIRE SPRINKLERS REQUIRED - See BFD memo dated 11-29-2007
***WUI Zone A requirements***Prescriptive component energy approach*** Permit for the construction of a new 1,885 sq. ft., two story (first story 1,283 sq. ft., below grade 602 sq. ft.) single family dwelling with 3 bedrooms, 3 bathrooms, approximately 308 sq. ft. of covered patio/porch and a 680 sq. ft. attached garage per the approved plans and any notations. R-1B zoning and setbacks per planning. MDH

A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please allow 24 hours for subgrade approval processing. Call Melissa Jannusch at 208-608-7168

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Melissa Jannusch at 208-608-7168.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Blower Door Test Results12/12/201812/13/201812/13/2018PPASS
DetailsTony Young
3283 code Phone #: ###-#### Inspection requested via web by David Wipper// 3.76
DOC - Permit Finaled12/13/201812/13/201812/13/2018PPASS
DetailsTony Young
c of o issued
BLD-Final12/12/201812/13/201812/13/2018PPASS
DetailsTony Young
3283 code Phone #: ###-#### Inspection requested via web by David Wipper// B D 3.76
BLD-Final12/12/201812/12/201812/12/2018PPART
DetailsTony Young
3283 code Phone #: ###-#### Inspection requested via web by David Wipper,, ok just needs to verify public works hillside approval
BLD-Other10/3/201810/4/201810/8/2018ADONE
DetailsTony Young
Sofit - Larry Phone #: ###-####
BLD-Other9/27/20189/27/20189/27/2018PPART
DetailsJim Storey
sofit- Larry Phone #: ###-#### need fire rated listings for can lights.
BLD-Energy code compliance9/26/20189/27/20189/27/2018APASS
DetailsDave Hannah
Larry Phone #: ###-####
BLD-Framing/Rough-in9/21/20189/21/20189/21/2018PPART
DetailsTony Young
Larry Phone #: ###-####,, see paint,, tighten all nuts in the sill plate bolts,, seal holes in the plates,, add hanger on upstairs hip ridge jack,, fire block the double wall top plates,, (can be insulation),, see paint,, will need one more tenting inspection from the sprinkler inspector prior to energy code passing for cover,, ok to insulate after fixes
BLD-Wall Bracing9/17/20189/18/20189/18/2018PPART
DetailsTony Young
Shear wall re inspection Phone #: ###-#### Inspection requested via web by David Wipper,, exterior ok now
BLD-Wall Bracing9/12/20189/13/20189/13/2018APART
DetailsMike Jordan
Shear // Larry Phone #: ###-####. exterior shear nailing ok. Noted one simpson STHD 14 placed in wrong location in middle of lower window, soyth wall. Will need to have engineer provide alternate fix. Will verify on framing inspection.
BLD-Wall Bracing9/11/20189/12/20189/12/2018ANR
DetailsDave Hannah
Shear // Larry Phone #: ###-####
BLD-Foundation8/6/20188/6/20188/6/2018PPASS
DetailsBrandon Shaw
Work in progress
BLD-Footing7/31/20187/31/20187/31/2018APASS
DetailsBrandon Shaw
BLD-Footing7/30/20187/31/20187/31/2018AFAIL
DetailsBrandon Shaw
Need subgrade approval
BLD-Footing7/27/20187/30/20187/30/2018APEND
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Ben Sears,, needs approval from the office 1st,,
BLD-Footing7/27/20187/27/20187/27/2018PNR
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Ben Sears,, needs soils