Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberBLD18-02154
StatusFinaled
Name HHS CONSTRUCTION LLC
Site Address 3747 S HARRIS RANCH AVE
Project NameWildflower BJ 2-7
Customer Number 
ePlanReviewYes
Description
***Prescriptive component energy approach*** Permit for the construction of a new 2123 sq. ft., two story (first story 1318 sq. ft., second story 805 sq. ft.) single family dwelling with 3 bedrooms, 2.5 bathrooms, approximately 54 sq. ft. of covered patio/porch and a 441 sq. ft. attached garage per the approved plans, plan review report and any notations. SP-01 zoning and setbacks per planning. MDH
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final3/21/20193/21/20193/21/2019PPASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Gus Brandon
DOC - Permit Finaled3/21/20193/21/20193/21/2019PPASS
DetailsBrandon Shaw
BLD-Blower Door Test Results3/21/20193/21/20193/21/2019PDONE
DetailsBrandon Shaw
ACH50- 3.85
BLD-Final3/14/20193/19/20193/19/2019ANR
DetailsBrandon Shaw
Need blower door test results posted...
BLD-Framing/Rough-in1/14/20191/14/20191/14/2019PPASS
DetailsBrandon Shaw
Corrections SAT...
OK to insulate...
BLD-Framing/Rough-in1/4/20191/4/20191/4/2019PFAIL
DetailsBrandon Shaw
Shear corrections not complete...
Approved plans show 10 HDU4 hold downs, onle 8 installed...
No floor to floor MSTA24 straps at second floor...
Strap needed at garage bearing wall...
Per S1.1, note #10 A35 clips need to be installed, two locations...
See Plans and red paint...
BLD-Other1/4/20191/4/20191/4/2019PPASS
DetailsBrandon Shaw
Soffit
BLD-Framing/Rough-in12/26/201812/27/201812/27/2018PNR
DetailsBrandon Shaw
Late as possible. I have air seal coming tomorrow. Phone #: ###-#### Inspection requested via web by Gus Brandon
BLD-Wall Bracing12/7/201812/7/201812/7/2018PFAIL
DetailsBrandon Shaw
Need a complete set of approved plans...
Achor botls to be no more than 12" from end of sill plates...
Hold downs and anchor bolts missing hardware...
First floor only...
See Red Paint
BLD-Foundation10/18/201810/18/201810/18/2018APASS
DetailsJim Storey
As late as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell
BLD-Footing10/17/201810/17/201810/17/2018PPASS
DetailsBrandon Shaw
Work in progress
BLD-Footing10/11/201810/12/201810/11/2018ACANC
DetailsBrandon Shaw
10 am please- Phone #: 2088031073 >> Inspection requested via mobile web by Alex Arambul Inspection cancelled via mobile web on Thursday, October 11, 2018.
BLD-Conference10/11/201810/12/201810/11/2018ACANC
DetailsBrandon Shaw
As late as possible Phone #: 2088031073 >> Inspection requested via mobile web by Alex Arambul Inspection cancelled via mobile web on Thursday, October 11, 2018.
BLD-Footing10/10/201810/11/201810/11/2018PCANC
DetailsBrandon Shaw
As late as possible Phone #: 2088031073 >> Inspection requested via mobile web by Alex Arambul Inspection cancelled via mobile web on Thursday, October 11, 2018.
BLD-Conference10/10/201810/11/201810/10/2018PCANC
DetailsBrandon Shaw
As late as possible Phone #: 2088031073 >> Inspection requested via mobile web by Alex Arambul Inspection cancelled via mobile web on Wednesday, October 10, 2018.