Permit Information
Permit NumberBLD18-02546
StatusFinaled
Name PRUETT CONSTRUCTION LLC
Site Address 1747 N FAIRMEADOW DR
Project NameVillage Charter School
Customer Number 
ePlanReviewYes
Description
(VILLAGE CHARTER SCHOOL – BUILDING 2) Permit is to remodel an existing 9,800 sq. ft. educational/assembly building. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of select interior nonbearing walls, removal of select existing gym wall opening infill, removal of select door/door frame, construction of interior non-bearing walls to create a resource room, an office, a smaller computer lab, (3) multi-age classrooms, a hallway and a vestibule, new door/door frames, new accessible 2” sloped elevation change at vestibule, relocate existing light fixtures, electrical work and interior finishes in compliance with Ch. 8 of the current IBC. Note: plumbing fixture count in conjunction with adjacent building operating together and adjacent building shall be made available at all times the gym is occupied, per agreement letter under BLD16-00161. This building is fully Fire Sprinklered. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final10/19/201810/19/201810/19/2018PPASS
DetailsJim Sly
Plans on top of black file cabinet in hall Phone #: ###-#### Inspection requested via web by Vaughn Pruett
DOC - Permit Finaled10/19/201810/19/201810/19/2018PPASS
DetailsJim Sly
FIRE-Final Inspection10/19/201810/19/201810/19/2018PPASS
DetailsTroy Cobbley
Life safety passed

Von Phone #: ###-####
BLD-Final10/18/201810/19/201810/19/2018ANR
DetailsJim Sly
Plans are on the black file cabinet in the hall- please call 30 minutes before to meet onsite. Thanks. Phone #: ###-#### Inspection requested via web by Vaughn Pruett
Need fire final 1st
FIRE-Final Inspection9/24/20189/25/20189/25/2018AFAIL
DetailsTroy Cobbley
No plans or small documents on site. I did a quick inspection and noted that fire alarm modifications will be needed due to the new walls. Sprinkler protection appears ok.


Call before and please see front office for access. Thanks. Phone #: ###-#### Inspection requested via web by Vaughn Pruett
BLD-Final9/21/20189/24/20189/24/2018ANR
DetailsJim Storey
Please visit main office to be let into space. Thanks. Phone #: ###-#### Inspection requested via web by Vaughn Pruett need fire
BLD-Framing/Rough-in8/14/20188/15/20188/15/2018APASS
DetailsJim Sly
Phone #: ###-#### Inspection requested via web by Vaughn Pruett