Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberBLD18-02644
StatusFinaled
Name HC COMPANY INC
Site Address 707 N ARMSTRONG PL
Project NameCDHD Interior Remodel
Customer Number 
ePlanReviewYes
Description
(CENTRAL DISTRICT HEALTH DEPARTMENT (CDHD) – INTERIOR REMODEL) (10-14-19 PLAN MODIFICATION TO CONSTRUCT AN INTERIOR NONBEARING WALL TO SEPARATE OFFICE 357 FROM A STORAGE AND HALLWAY AREA.) (10-7-19 PLAN MODIFICATION TO ENCLOSE ELECTRICAL EQUIPMENT IN A ROOM (I.E. ELECTRICAL ROOM 150) AND TO ADD A LIGHT FIXTURE AND SWITCH. WORK IS TO INCLUDE A WALL AND A DOOR.) (5-29-19 PLAN MODIFICATION TO CONVERT HALF OF AN EXISTING STORAGE ROOM INTO A JANITOR’S CLOSET. WORK INCLUDES AN INTERIOR NONBEARING WALL, MOP SINK, PLUMBING, AND AN EXHAUST FAN.) The fire sprinkler system is used for building area increase and for code trade-offs. To remodel about 20,000 square feet of area within an existing 42,606 square foot building for the existing whole building tenant. A large portion of this building is used as an outpatient medical clinic where no one is rendered incapable of self-preservation. Work includes interior nonbearing walls, interior doors, interior windows, five (5) single-user toilet rooms accessible to the disabled, a new exterior door, suspended acoustical ceilings, gypsum board ceilings and soffits, millwork, and finishes. Structural work includes reinforced concrete footings, enlarged existing reinforced concrete footings, steel columns with steel base plates and anchor bolts, and wood beams. Special Inspection is required for soils, concrete, post-installed anchors in hardened concrete, and for steel fabrication including welding. The proposed work will be done in phases. A compliant means of egress is required to be maintained from each occupied portion of this building for the duration of the construction project. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. This permit is intended to establish a new Certificate of Occupancy for the entire building. The fire sprinkler system is required to comply with NFPA 13, including changing all fire sprinkler heads to quick-response, and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final12/10/201912/11/201912/11/2019PPASS
DetailsMike Jordan
Jason Phone #: ###-####
DOC - Permit Finaled12/11/201912/11/201912/11/2019PPASS
DetailsMike Jordan
FIRE-Final Inspection12/10/201912/11/201912/11/2019APASS
DetailsTroy Cobbley
Life safety passed.

Jason - ###-####
FIRE-Conference12/6/201912/6/201912/6/2019PDONE
DetailsTroy Cobbley
Jason and I went over life safety requirements for the remaining phase of work for this project. Need verification that exit discharge lights will not be required out of the two remaining marked exits.
BLD-Ceiling Grid Inspection11/20/201911/20/201911/20/2019PPASS
DetailsMike Jordan
Jason Phone #: ###-####
BLD-Framing/Rough-in10/11/201910/11/201910/11/2019PPASS
DetailsBrandon Shaw
Final phase...
BLD-Final8/16/20198/19/20198/19/2019APART
DetailsMike Jordan
CAMERON Phone #: ###-####. ,Phase 2 ok to occupy.
BLD-Final8/14/20198/16/20198/16/2019PCANC
DetailsMike Jordan
Cameron Phone #: ###-####
FIRE-Final Inspection8/14/20198/15/20198/15/2019AFAIL
DetailsTroy Cobbley
This life safety inspection was for Phase 2. The phase 2 fire sprinkler and fire alarm work needs to be completed. I noted exit signs missing and one area that needs the exit sign repaired and emergency lighting provided.. Also Jason agreed that an old aluminum door with a deadbolt will be removed.

Jason Phone #: ###-####
BLD-Ceiling Grid Inspection7/16/20197/17/20197/17/2019APASS
DetailsMike Jordan
Jason Phone #: ###-####
BLD-Ceiling Grid Inspection7/2/20197/3/20197/3/2019PPART
DetailsMike Jordan
Cameron Phone #: ###-####-please call prior to meet. Ceiling grid in phase 2 ok pending MEP's rough in inspections.
BLD-Framing/Rough-in5/16/20195/16/20195/16/2019PPASS
DetailsMike Jordan
Jason Phone #: ###-####. Interior steel stud framed walls only for phase 2 ok.
BLD-Framing/Rough-in5/14/20195/14/20195/14/2019PNR
DetailsMike Jordan
Jason Phone #: ###-####. Needs plumbing and electrical rough in inspections first.
BLD-Final3/27/20193/27/20193/27/2019PPART
DetailsMike Jordan
jason Phone #: ###-####. Ok to occupy phase 1.
FIRE-Final Inspection3/27/20193/27/20193/27/2019PPART
DetailsTroy Cobbley
Life safety passed for the phase 1 area of work.

jason Phone #: ###-####
BLD-Final3/26/20193/26/20193/26/2019PNR
DetailsMike Jordan
Jason Phone #: ###-####
FIRE-Final Inspection3/25/20193/26/20193/26/2019AFAIL
DetailsTroy Cobbley
Need panic hardware as shown on the approved drawings, need occupant load signs, need addtional emergency lights/exit discharge lights as discussed.

Jason Phone #: ###-####
FIRE-Conference3/18/20193/18/20193/18/2019PDONE
DetailsTroy Cobbley
Jason and I spoke about fire sprinkler and fire alarm isuues that need addressed prior to a phase 1 approval.
BLD-Ceiling Grid Inspection1/28/20191/28/20191/28/2019PPART
DetailsMike Jordan
jason Phone #: ###-####..Ceiling grid for phase 1 ok pending MEP's.
BLD-Framing/Rough-in1/10/20191/11/20191/11/2019APASS
DetailsMike Jordan
Jason Phone #: ###-####. Hardlids and soffits for phase 1 area A. Pending fire sprinkler rough in inspection.
BLD-Framing/Rough-in12/17/201812/18/201812/18/2018PPASS
DetailsMike Jordan
Jason Phone #: ###-####. INterior stel stud framed walls for phase 1. Grids 3 to 8.