Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberBLD18-02971
StatusIssued
Name DREAM WEAVER CONSTRUCTION SERVICES
Site Address 2139 S BROADWAY AVE Unit: STE 102
Project NameCritty's Tap Room
Customer Number 
ePlanReviewYes
Description
(CRITTY'S TAP ROOM - SUITE 102) This building does not have a fire sprinkler system. Permit is for the remodel of an existing 1,272 sq. ft. title loan office into a bar/tap room. Work to include a serving area with 26 beer taps, 6 wine taps, new interior non-bearing partitions, new seating area, beer/wine bar, plumbing, electrical, and storage for kegs/beverages. Existing HVAC to remain and no additional light fixtures under this permit. New interior finishes in compliance with Ch. 8 of the 2012 IBC. A 2-hour fire barrier shall be installed in the concealed space of the exterior canopy to divide the building into (2) two fire areas to avoid the installation of an automatic sprinkler system per IBC Section 903.2.1.2. All work to be done per the approved plans and applicable codes and ordinances. **JHB**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Aging Inspection11/29/201911/29/201912/2/2019 PART
DetailsJim Storey
not open yet pending sign offs
BLD-Final7/18/20197/18/20197/18/2019PPART
DetailsJim Storey
tAG Phone #: ###-####
BLD-Framing/Rough-in7/18/20197/18/20197/18/2019PPASS
DetailsJim Storey
tAG Phone #: ###-#### rated const ok to cover
BLD-Framing/Rough-in12/27/201812/28/201812/28/2018APASS
DetailsJim Storey
Tad Phone #: ###-#### framing ok pending trades
BLD-Framing/Rough-in12/10/201812/11/201812/11/2018APASS
DetailsMike Jordan
Tad-Partial Phone #: ###-####. fir outs only ok.
BLD-Conference11/8/201811/9/201811/9/2018AFAIL
DetailsJim Storey
Tad Phone #: ###-#### not a 2hr wall east // have arch field review and resub mit to planreview as to how to proceed to not require fire spk.