Permit Information
Permit NumberBLD18-03116
StatusFinaled
Name BILTMORE COMPANY
Site Address 11792 W KING ST
Project NameFairview Apartments - Bldg 1
Customer Number 
ePlanReviewYes
Description
(FAIRVIEW APARTMENTS) (BLDG 1) (DRH17-00532) (GRD18-00035) Permit for the construction of Building 1, a 27,059 sq ft, 3-story, 24-unit apartment building. This building is one of six buildings within a multi-family development, which includes (3) three-story, 24-unit multi-family buildings and (3) two-story, 8-unit buildings for a total of 96 units on the site. Work to include general site work and the construction of the new building per the approved plans. Special inspections required per the attached Form 310. All buildings are to be fully fire sprinklered with an NFPA 13-R system as required for residential occupancy and story increase. **JAR**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final10/16/201910/16/201910/16/2019PPASS
DetailsTell Riley
PAT Phone #: ###-####//trades finals complete//signatures required complete//final complete//archtect approved alternate on type a unit//
BLD-Final10/14/201910/15/201910/15/2019PCANC
DetailsTell Riley
Pat Phone #: ###-####
BLD-Final8/20/20198/21/20198/21/2019APART
DetailsTell Riley
Matt Phone #: ###-####//final 12 units walk through//still need plan review approval of architects change to type A unit///
ok for temp c of o once we get changes architure
FIRE-Final Inspection8/19/20198/21/20198/21/2019APASS
DetailsTroy Cobbley
life safety passed.

Matt Phone #: ###-####
FIRE-Hydro test above ground8/20/20198/20/20198/20/2019PFAIL
DetailsTroy Cobbley
One pendant sprinkler head needs adjusted in the second floor, west side, south end apartment.
BLD-Final8/20/20198/20/20198/20/2019PCANC
DetailsTell Riley
Matt Phone #: ###-####//cancel per Matt//
BLD-Final8/15/20198/16/20198/16/2019APART
DetailsTell Riley
Matt Phone #: ###-####//105,106,205,206,305,306//ok for temp occupancy//get plan review approval on letter of type A unit from architect//
BLD-Final8/5/20198/5/20198/5/2019PPART
DetailsTell Riley
Matt Phone #: ###-####//first six units temp occupancy ok//
FIRE-Final Inspection8/2/20198/5/20198/5/2019APART
DetailsTroy Cobbley
The second group (six) of apartments to the north of the central breeze way life safety is passed. Matt Phone #: ###-####
BLD-Final7/26/20197/29/20197/29/2019ANR
DetailsTell Riley
Matt Phone #: ###-####//need final plumbing on units 107,108,207,208,307,308//
BLD-Final7/22/20197/23/20197/23/2019AFAIL
DetailsTell Riley
Bill Phone #: ###-####//7's and 8's// see list onsite for corrections//
FIRE-Final Inspection7/22/20197/22/20197/22/2019PPART
DetailsTroy Cobbley
Life safety is passed for the six north nmost apartments. Bill Phone #: ###-####
BLD-Energy code compliance6/6/20196/6/20196/6/2019PPASS
DetailsBrandon Shaw
BLD-Energy code compliance6/5/20196/5/20196/5/2019PNR
DetailsMike Jordan
Bill Phone #: ###-####
BLD-Framing/Rough-in6/4/20196/4/20196/4/2019PPART
DetailsTony Young
Bill Phone #: ###-####,, ok to insulate only. check truss bracing and fire penetrations at energy.
BLD-Energy code compliance5/24/20195/24/20195/24/2019PPASS
DetailsJim Sly
Bill Phone #: ###-####
BLD-Framing/Rough-in5/23/20195/23/20195/23/2019PPASS
DetailsJim Sly
Bill Phone #: ###-####
BLD-Energy code compliance5/10/20195/10/20195/10/2019PPART
DetailsJim Sly
Bill Phone #: ###-####
OK for 6 units listed on prior inspection
BLD-Framing/Rough-in5/9/20195/9/20195/9/2019PPASS
DetailsJim Sly
Bill-6 units-105,205,305,106,206,306 Phone #: ###-####
BLD-Energy code compliance4/26/20194/26/20194/26/2019PPART
DetailsDave Hannah
Bill Phone #: ###-#### first six units
BLD-Framing/Rough-in4/24/20194/24/20194/24/2019PPASS
DetailsJim Sly
Bill- inspection for units 107, 108, 207, 208, 308 Phone #: ###-####
BLD-Wall Bracing4/11/20194/12/20194/15/2019APASS
DetailsJim Sly
Bill Phone #: ###-####
BLD-Conference3/26/20193/27/20193/27/2019ACANC
DetailsJim Sly
Bill Phone #: ###-####
BLD-Foundation2/4/20192/4/20192/4/2019PPASS
DetailsJim Sly
Dane Phone #: ###-####
BLD-Foundation1/30/20191/31/20192/1/2019PPART
DetailsTony Young
Dane Phone #: ###-####
BLD-Footing1/29/20191/30/20191/30/2019PPASS
DetailsJim Sly
Dane Phone #: ###-####
BLD-Footing1/28/20191/28/20191/28/2019PPART
DetailsBrandon Shaw
BLDG A...
Work in progress...