Permit Information
Permit NumberBLD18-03249
StatusFinaled
Name FABIAN R NOEL
Site Address 5569 N COLLISTER DR
Project Name5569 N Collister-Noel Res
Customer Number 
ePlanReviewYes
Description
**PLAN MODIFICATION - changing retaining walls from poured concrete to block, locations and heights do not change 04-30-19 JJN** |>FIRE SPRINKLERS REQUIRED<| **WUI FOOTHILLS ZONE 'A'** **PRESCRIPTIVE ENERGY REQUIREMENTS** **310 SPECIAL INSPECTIONS** Permit for the construction of a new 2848 sq. ft., two story (first story 1280 sq. ft., second story 813 sq. ft. basement 755 sq. ft.) single family dwelling with 4 bedrooms, 3.5 bathrooms, approximately a 480 sq. ft. attached garage per the approved plans and any notations. R-1B zoning and setbacks per planning. A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at 208-608-7168 with questions.

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Melissa Jannusch at 208-608-7168.

The final inspection of the site grading and drainage work shall be done by the design engineer. Written approval shall be submitted to Boise Public Works prior to the issuance of the building final.

An erosion and sediment control site preparation inspection is required for this site. The site preparation inspection takes place after all required erosion and sediment control best management practices have been installed and BEFORE any earthwork takes place. Call 208-608-7070 to schedule an inspection. JJN

Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final12/26/201912/27/201912/27/2019PPASS
DetailsTony Young
Noel Phone #: ###-####
BLD-Blower Door Test Results12/27/201912/27/201912/27/2019PPASS
DetailsTony Young
Noel Phone #: ###-####.. 3.48
DOC - Permit Finaled12/27/201912/27/201912/27/2019PPASS
DetailsTony Young
BLD-Conference12/20/201912/23/201912/23/2019APART
DetailsTony Young
Fabian Phone #: ###-####,, walk through on the final,, needs hillside PW pass,, needs guard rail and hand rail to meet code,, needs fire seperation in the garage..
BLD-Aging Inspection12/10/201912/10/201912/11/2019 PEND
DetailsTony Young
BLD-Conference10/15/201910/16/201910/16/2019APASS
DetailsTony Young
Noel Phone #: ###-####,, stair ?s
BLD-Framing/Rough-in7/26/20197/29/20197/29/2019APART
DetailsTony Young
Chet Phone #: ###-####,, needs to seal chases,, ok to insulate
BLD-Framing/Rough-in7/25/20197/26/20197/26/2019PNR
DetailsTony Young
Chet Phone #: ###-####,,conf. walk through only,, needs trades,, needs tempered glass by final,, temp stairs in now,, verify stairs at the final.. needs fire blocking of chases,, plates
BLD-Concrete3/20/20193/21/20193/21/2019APART
DetailsTony Young
Phone #: 2088616923 >> Inspection requested via mobile web by Fabian Noel,, work in progress on upper level ICF walls
BLD-Concrete3/18/20193/20/20193/20/2019PNR
DetailsDave Hannah
Phone #: 2088616923 >> Inspection requested via mobile web by Fabian Noel
BLD-Foundation3/1/20193/1/20193/1/2019PPART
DetailsTony Young
rebar// sabian Phone #: ###-####,, icf block wall,, mid wall ok to grout
BLD-Concrete1/14/20191/17/20191/17/2019APART
DetailsMike Jordan
Phone #: 2088806738 >> Inspection requested via mobile web by Chet Clark. ICF permiter wall from top of footing to 10ft. 8 inch elev. Needs to tie verts in place and complet lintel steel.
BLD-Footing1/8/20191/10/20191/10/2019APASS
DetailsBrandon Shaw
First story footings...
Work in progress...
BLD-Wall Bracing12/1/201812/5/201812/5/2018APART
DetailsTony Young
As early as possible Phone #: 2088616923 >> Inspection requested via mobile web by Fabian Noel,, upper retaining wall,, work in progress,, will tent and heat for freezing temps
BLD-Footing11/20/201811/26/201811/26/2018APART
DetailsTony Young
As early as possible Phone #: 2088616923 >> Inspection requested via mobile web by Fabian Noel,, upper retaining wall ok
BLD-Footing11/17/201811/19/201811/17/2018ACANC
DetailsTony Young
As early as possible Phone #: 2088616923 >> Inspection requested via mobile web by Fabian Noel Inspection cancelled via mobile web on Saturday, November 17, 2018.