Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberBLD18-03644
StatusFinaled
Name WOOD SOLUTIONS LLC
Site Address 1651 S RIVERSTONE LN
Project NameCottonwood Apts - Bldg 2
Customer NumberEPLAN BLD18-03640 & 03644-03655
ePlanReviewYes
Description
(COTTONWOOD APARTMENTS) (13 BUILDING PERMITS FILED UNDER BLD18-03640) (BUILDING 2) // 2-28-19 PLAN MOD TO REVISE GLU-LAM BEAM SIZE AT EXPOSED WALKWAY SUPPORT TO QUALIFY AS HEAVY TIMBER AND REVISE DETAIL OF DIMENSIONAL WALKWAY SUPPORT BEAM TO INCLUDE FULL GWB WRAP FOR FIREPROOFING. INCLUDE NEW COLUMN SPLICE DETAIL FOR REPLACING DAMAGED PORTIONS OF HEAVY TIMBER COLUMNS. JAR // Permit to replace exterior stairs throughout an existing multi-family housing complex. Thirteen sets of stairs will be constructed on (13) two-story buildings. All buildings are of Type VA construction, requiring building elements to have 1-hour fire resistance rated construction. Rated construction to be maintained or repaired to maintain 1-hour rating. Work to include: repair and replacement of damaged siding; demolition of egress balcony, demolition of existing exterior stair and stair guardrails; installation of new egress balcony, stair structure, stairs, and guardrails at stairs and balconies. Special inspections required per attached Form 310. Approval is contingent upon adhering to the approved plans on file and attached engineering. This is a scope of work permit only with a certificate of completion to be issued upon completion and approval of the project. This building is NOT Fire Sprinklered. **JAR**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
DOC - Permit Finaled12/12/201912/12/201912/12/2019PPASS
DetailsJim Storey
BLD-Final12/11/201912/12/201912/12/2019PPASS
DetailsJim Storey
Prefer 1pm if possible Phone #: ###-#### Inspection requested via web by Jimmy Martin
BLD-Framing/Rough-in12/10/201912/11/201912/11/2019APASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Jimmy Martin
FIRE-Final Inspection12/10/201912/11/201912/11/2019APASS
DetailsJim Page
Final life fire safety inspection for scope of work complete, signature card not available at time of inspection.

Phone #: ###-#### Inspection requested via web by Jimmy Martin
BLD-Framing/Rough-in11/26/201911/27/201911/26/2019ACANC
DetailsBrandon Shaw
Phone #: ###-#### >> Inspection requested via web by Jimmy Martin Inspection cancelled from web by: Jimmy Martin
BLD-Aging Inspection11/8/201911/8/201911/8/2019 DONE
DetailsBrandon Shaw
Extend Permit 90/180 days11/8/201911/8/201911/8/2019PDEFR