Permit Information
Permit NumberBLD18-03833
StatusFinaled
Name WOODLAND KIDS
Site Address 10487 W FAIRVIEW AVE
Project NameWoodland Kids
Customer Number 
ePlanReviewYes
Description
(WOODLAND KIDS – TENANT IMPROVEMENT) (5-22-19 PLAN MODIFICATION TO INSTALL 3-HR FIRE DAMPERS WHERE DUCTS PENETRATE A 3-HR FIRE BARRIER WALL THAT FUNCTIONS AS A 3-HR FIRE WALL PER THE 2015 IEBC.) (4-9-18 PLAN MODIFICATION TO REMOVE THE PREVIOUSLY PROPOSED POWERED EXHAUST FROM TWO EXISTING ROOF TOP HVAC UNITS.) The fire sprinkler system is used for unlimited area of the building AND to allow 3-hr fire barrier walls in lieu of fire walls. The fire sprinkler system is NOT allowed to be used for building area increase for A Occupancies. To remodel an existing 11,286 square foot tenant space to be used as an indoor play area for toddlers and school-age kids. A parent or a guardian is required to be on site with each child at all times. This tenant is not a child daycare facility. Work is to include interior nonbearing walls, 2 multi-user toilet rooms accessible to the disabled, a “high” and a “low” drinking fountain, an elevated platform (30” max.) play structure, interior doors, interior windows, a 3-hr fire barrier wall, suspended acoustical ceilings, gypsum board ceilings, ceilings open to the painted roof structure above, log structure, ceiling and wall structures, millwork, and finishes. Special Inspection is required for welding and for post-installed anchors in hardened concrete. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. Except for the platform play structure, all of the floor areas are at the same level. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/10/20196/11/20196/11/2019APASS
DetailsMike Jordan
Allen Phone #: ###-####. ok for perm occ.
FIRE-Final Inspection6/6/20196/6/20196/6/2019PCANC
DetailsTroy Cobbley
Cody Phone #: ###-#### Inspection cancelled via mobile web on Thursday, June 06, 2019.
FIRE-Final Inspection6/6/20196/6/20196/6/2019APASS
DetailsJim Page
Fire sprinkler inspection complete, fire alarm inspection complete, fire extinguishers are placed with current inspection tags. Final life fire safety inspection for area of work complete.

BLD-Framing/Rough-in5/1/20195/1/20195/1/2019PPASS
DetailsMike Jordan
Cody Phone #: ###-####. BAse layers for 3hr. fire barrier and partial 2nd. layer.
BLD-Conference4/24/20194/24/20194/24/2019PDONE
DetailsMike Jordan
Todd Phone #: ###-####. Went over UL assembly for 3hr. fire barrier with contractor.
BLD-Framing/Rough-in4/23/20194/23/20194/23/2019PPART
DetailsMike Jordan
Todd Phone #: ###-####. Interior steel stud framed walls, except for 3hr. hr fire barier ok for cover. Pending plumbing rough in inspection.
BLD-Conference4/16/20194/17/20194/17/2019ADONE
DetailsMike Jordan
Call half hour before to meet // Allen Phone #: ###-####
BLD-Framing/Rough-in4/11/20194/12/20194/12/2019APART
DetailsMike Jordan
Jr. Phone #: ###-####. Interior steel atud framed walls for 3hr. fire barier.