Permit Information
Permit NumberBLD18-03906
StatusFinaled
Name THE RUSSELL CORPORATION
Site Address 7805 W GRATZ DR
Project NameLyle Pearson Jaguar 1st Floor
Customer Number 
ePlanReviewYes
Description
(LYLE PEARSON JAGUAR/LAND ROVER/VOLVO) (1ST FLOOR REMODEL) //06/21/19 PLAN MOD FOR EXTERIOR SITE REVISIONS. JAR //05/13/19 PLAN MOD TO CHANGE LOCATION OF NORTH EXTERIOR WALL AND STOREFRONT WINDOWS. JAR // **Permit to remodel the first floor showroom of an existing auto dealership. Work to include: demolition of 158 sq ft building area; demolition and rebuild of front exterior façade and portion of roof; enclosing an existing covered exterior area; minor site work; new interior non-bearing partition walls; new doors; new interior relites; new ceiling and lighting; electrical, mechanical, and plumbing work; and new finishes to be in compliance with Ch. 8 of the 2015 IBC. Special inspections are required per the attached Form 310. A new certificate of occupancy is being issued for the original first floor footprint and for the second floor, excluding the addition constructed under BLD17-04568. Approval is contingent upon adhering to the approved plans on file and attached engineering. This building is fire sprinklered for area increase. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JAR**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final11/26/201911/26/201911/26/2019PPASS
DetailsMike Jordan
Please give me a call when you head this way. Phone #: ###-#### Inspection requested via web by Bob Thornton. Ok for perm occ.
FIRE-Final Inspection11/25/201911/26/201911/26/2019APASS
DetailsTroy Cobbley
life safety passed.

Phone #: ###-#### Inspection requested via web by Bob Thornton
FIRE-Final Inspection11/18/201911/19/201911/19/2019PFAIL
DetailsTroy Cobbley
Provide annual inspection for the fire sprinkler system and fire extinguishers. Provide interconnect of the door mags and the fire alarm system as per the iFC. This work requires permit.

Call me when you’re headed this way. Phone #: ###-#### Inspection requested via web by Bob Thornton
BLD-Ceiling Grid Inspection10/23/201910/24/201910/24/2019APASS
DetailsMike Jordan
Call me when you’re headed this way please. Phone #: ###-#### Inspection requested via web by Bob Thornton
BLD-Framing/Rough-in8/28/20198/29/20198/29/2019APASS
DetailsMike Jordan
Inspect fat grid from grid line 4 east. Phone #: ###-#### Inspection requested via web by Bob Thornton
BLD-Ceiling Grid Inspection8/29/20198/29/20198/29/2019APASS
DetailsMike Jordan
Inspect fat grid from grid line 4 east. Phone #: ###-#### Inspection requested via web by Bob Thornton
BLD-Energy code compliance8/27/20198/27/20198/27/2019PPASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Bob Thornton
BLD-Framing/Rough-in8/21/20198/21/20198/21/2019PPASS
DetailsMike Jordan
Please look at exterior walls for cover. Phone #: ###-#### Inspection requested via web by Bob Thornton. Ok to insulate exterior walls.
BLD-Wall cover8/12/20198/13/20198/13/2019APASS
DetailsMike Jordan
Look at vestibule walls. Phone #: ###-#### Inspection requested via web by Bob Thornton
BLD-Wall Bracing8/13/20198/13/20198/13/2019APASS
DetailsMike Jordan
Look at vestibule walls. Phone #: ###-#### Inspection requested via web by Bob Thornton. Parapet wall bracing is now ok.
BLD-Wall cover8/6/20198/7/20198/7/2019PCANC
DetailsMike Jordan
Parapet wall bracing. Give me a call. Phone #: ###-#### Inspection requested via web by Bob Thornton
BLD-Framing/Rough-in8/7/20198/7/20198/7/2019PPASS
DetailsMike Jordan
Parapet wall bracing. Give me a call. Phone #: ###-#### Inspection requested via web by Bob Thornton
BLD-Wall Bracing8/7/20198/7/20198/7/2019PFAIL
DetailsMike Jordan
Parapet wall bracing. Give me a call. Phone #: ###-#### Inspection requested via web by Bob Thornton
BLD-Wall cover8/6/20198/6/20198/6/2019PCANC
DetailsMike Jordan
Look at the roof wall bracing. Phone #: ###-#### >> Inspection requested via web by Bob Thornton Inspection cancelled from web by: Bob Thornton
BLD-Framing/Rough-in8/2/20198/2/20198/2/2019PPASS
DetailsMike Jordan
Partial framing. Give me a call. Phone #: ###-#### Inspection requested via web by Bob Thornton. West side parapet wall ok per RFI from engineer.
BLD-Framing/Rough-in7/29/20197/29/20197/29/2019PPASS
DetailsMike Jordan
Partial framing. Give me a call. Phone #: ###-#### Inspection requested via web by Bob Thornton. Stell stud framing for exterior canopies and store front.
FIRE-Conference7/12/20197/15/20197/15/2019ADONE
DetailsTroy Cobbley
Bob and I discussed a concealed space that will be built as "non-combustible" therefore not requireing fire sprinkler protection. Please call when you head this way. Phone #: ###-#### Inspection requested via web by Bob Thornton
BLD-Framing/Rough-in7/11/20197/12/20197/12/2019ACANC
DetailsMike Jordan
Bob- please call before arriving Phone #: ###-####
BLD-Conference7/12/20197/12/20197/12/2019ADONE
DetailsMike Jordan
Bob- please call before arriving Phone #: ###-####
BLD-Footing6/20/20196/20/20196/20/2019PPART
DetailsMike Jordan
Bob-footing for building portion only-per Bob plan mod not for this portion Phone #: ###-####. Footings for new store front. WIP. Will be ok for concrete pending special inspection.
BLD-Footing6/6/20196/6/20196/6/2019PDEFR
DetailsMike Jordan
Bob Phone #: ###-####. Concrete placed in the am. Special inspector on site.