Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberBLD18-04159
StatusFinaled
Name FALASH & COMPANY INC
Site Address 1702 W FAIRVIEW AVE
Project NameGustavel Orthopedics
Customer NumberBLD18-03967 DEMO
ePlanReviewYes
Description
(GUSTAVEL ORTHOPEDICS – KING BUILDING) //Plan modifications to stair structural framing, door relocation, door swing, interior wall layout shift and revise type/size of select exterior windows. 1-07-2019 JG// Permit is to remodel an existing 4,323 sq. ft. building (2,203 sq. ft. 1st story + 1,551 sq. ft. 2nd story and about 600sq. ft. exterior patio). Approval is contingent upon adhering to the approved plans on file, plan review report and attached engineering. Work to include: removal of exterior and select interior windows, removal of interior nonbearing walls, removal of select interior bearing wall, removal of select door/door frames and relocate, removal of interior stairs and guards, removal of select millwork, construction of interior non-bearing walls to create (3) exam rooms, a reception/lobby area, an X-Ray room, a casting room, a nurse’s area, an accessible restroom, (3) offices, a break room, a storage room, a lounge area and an open office area, new interior stairs, new raised floor landing, new exterior metal canopy, new exterior store front and interior windows, select new door/door frames, select new exterior wall infill, new Hi/Lo drinking fountain, select ne gypsum ceiling, electrical work, plumbing work, mechanical work and interior finishes in compliance with Ch. 8 of the current IBC. Note: special inspection required, see attached form 310. This building is Not Fire Sprinklered. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final3/7/20193/8/20193/11/2019APASS
DetailsDave Hannah
Greg Phone #: ###-####
BLD-Final3/5/20193/5/20193/5/2019PPART
DetailsDave Hannah
Greg Phone #: ###-#### ok for tco needs to fix ada counter top break rm need engineering on cable gaurd rail wiondow stops ada signage handrails
FIRE-Final Inspection3/5/20193/5/20193/5/2019PPASS
DetailsJim Page
Previously noted items have been corrected, final life fire safety inspection for area of work complete.

Greg Phone #: ###-####
FIRE-Final Inspection3/4/20193/4/20193/4/2019PFAIL
DetailsJim Page
Emergency lighting does not match the city approved draiwngs. Provide emergency lighitng for exterior discharge per 2015 IFC section 1008. Provide fire extinguisher on level 2 as discussed.

gREG Phone #: ###-####
BLD-Ceiling Grid Inspection2/12/20192/13/20192/13/2019APASS
DetailsDave Hannah
Greg Phone #: ###-####
BLD-Framing/Rough-in1/3/20191/4/20191/4/2019PPASS
DetailsDave Hannah
DOES NOT HAVE TO DO WITH STAIRS OR SECOND FL FRAMING // Call 20 mins before to meet Greg Phone #: ###-####