Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberBLD18-04252
StatusFinaled
Name PETRA INC
Site Address 1129 S BROADWAY AVE
Project NameBroadway & Beacon Building
Customer Number 
ePlanReviewYes
Description
(BROADWAY & BEACON BUILDING - SHELL) (DRH18-00228) **NO OCCUPANCY ALLOWED UNDER THIS PERMIT. TENANT SHALL APPLY FOR CERTIFICATE OF OCCUPANCY PRIOR TO OCCUPYING THE SPACE. To construct a new one story, 1,945 square foot shell building (2,490 square feet projected roof area). This is a shell only permit. (Demo Permit: BLD18-00119) Future occupancies could include A2, B, and M. Future tenants are required to apply for their own permit to establish occupancy. Work is to include concrete continuous footings, wood framed exterior walls, concrete slab on grade, wood roof trusses, rigid insulation installed on top or the roof deck with a single ply membrane roof covering, primary and secondary roof drains, exterior storefront windows and doors. Minimal heating and lighting will be provided. Special Inspection is required for concrete and steel including welding. Special inspections required per attached Form 310 and include reinforcing steel, concrete, and adhesive anchors. Deferred submittals include the pre-engineered wooden roof trusses. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. Service sinks, toilet rooms, and perhaps drinking fountains for each tenant space will be required under future tenant improvement permits. **JHB**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/17/20199/18/20199/18/2019APASS
DetailsBrandon Shaw
shell ; Core building final Phone #: ###-#### Inspection requested via web by J.C. Murray
DOC - Permit Finaled9/18/20199/18/20199/18/2019PPASS
DetailsBrandon Shaw
FIRE-Final Inspection9/11/20199/11/20199/11/2019PPASS
DetailsMark Scharfen
Vanilla finish. Passed inspection. No occupancy on this permit.

fire/life ; safety, shell/core building Phone #: ###-#### Inspection requested via web by J.C. Murray
BLD-Framing/Rough-in7/1/20197/2/20197/2/2019APART
DetailsJim Storey
Chad Phone #: ###-#### pending roof r30 at crickets.
BLD-Energy code compliance5/21/20195/22/20195/22/2019APART
DetailsJim Storey
requested via mobile web by Mike Tracy foam main deck r 30 ok pending resolve on overbuilds as to access and insulation.
BLD-Energy code compliance5/20/20195/21/20195/21/2019ANR
DetailsJim Storey
requested via mobile web by Mike Tracy
BLD-Energy code compliance5/20/20195/20/20195/20/2019ACANC
DetailsJim Storey
requested via mobile web by Mike Tracy
BLD-Framing/Rough-in5/17/20195/20/20195/20/2019PPASS
DetailsJim Storey
Call prior to going Phone #: 2088032242 >> Inspection requested via mobile web by Mike Tracy roof and walls nailling ok
BLD-Foundation4/15/20194/15/20194/15/2019PPART
DetailsJim Storey
Matt-wall Phone #: ###-#### placed w/si
BLD-Foundation4/4/20194/9/20194/9/2019APASS
DetailsDave Hannah
Joe or call Matt ###-#### Phone #: ###-####