BLD-Final | 8/16/2019 | 8/16/2019 | 8/16/2019 | P | PASS |
Brandon Shaw
|
|
|
Phone #: ###-#### Inspection requested via web by Steve Hanson
|
DOC - Permit Finaled | 8/16/2019 | 8/16/2019 | 8/16/2019 | P | PASS |
Brandon Shaw
|
|
|
|
BLD-Final | 8/15/2019 | 8/16/2019 | 8/16/2019 | A | NR |
Brandon Shaw
|
|
|
House should be open. Please call with any questions.
Thanks! Phone #: ###-#### Inspection requested via web by Steve Hanson
|
BLD-Energy code compliance | 7/22/2019 | 7/22/2019 | 7/22/2019 | P | PASS |
Brandon Shaw
|
|
|
Corrections SAT...
|
BLD-Energy code compliance | 7/18/2019 | 7/19/2019 | 7/19/2019 | A | FAIL |
Jim Storey
|
|
|
Hi, Need an energy inspection for the storage area above detached garage. Thank you Phone #: ###-#### Inspection requested via web by Steve Hanson missing vappor barrior on walls with attic exposer.
|
BLD-Energy code compliance | 7/16/2019 | 7/17/2019 | 7/17/2019 | A | PART |
Brandon Shaw
|
|
|
Garage only...
|
BLD-Framing/Rough-in | 7/15/2019 | 7/15/2019 | 7/15/2019 | P | PASS |
Brandon Shaw
|
|
|
Living space above garage, framing rough-in...
|
BLD-Framing/Rough-in | 6/25/2019 | 6/26/2019 | 6/26/2019 | A | FAIL |
Tony Young
|
|
|
framing reinspection and energy for garage. Power and vent have been removed from area above garage. Phone #: ###-#### Inspection requested via web by Steve Hanson/// need review set of plans from the city to reflect as built on garage floor plan with fixtures as well as electrical,, needs re-inspection on trades after as built approvals from city review.
|
BLD-Framing/Rough-in | 6/18/2019 | 6/18/2019 | 6/18/2019 | P | FAIL |
Tony Young
|
|
|
Phone #: ###-#### Inspection requested via web by Steve Hanson,, SWO issued on upper garage area,, components are in for an Accessory dwelling unit (ADU), electrical, plumbing, etc, ,,remove or get approval,, lower area of garage needs fur downs if allowed to keep.. also need to verify mechanical has been looked at.. need to justify how the 1 hour seperation will be made if occupancy seperation is allowed.. ok to insulate lower area in garage if desired
|
BLD-Framing/Rough-in | 6/4/2019 | 6/5/2019 | 6/5/2019 | P | NR |
Tony Young
|
|
|
We need a framing/rough-in inspection for the detached garage please. Thank you Phone #: ###-#### Inspection requested via web by Steve Hanson,,, needs trades 1st
|
BLD-Framing/Rough-in | 5/17/2019 | 5/17/2019 | 5/17/2019 | P | PASS |
Brandon Shaw
|
|
|
Correctiions SAT...
|
BLD-Energy code compliance | 5/16/2019 | 5/16/2019 | 5/17/2019 | P | PEND |
Brandon Shaw
|
|
|
No ceiling cover- need Truss Engineering
|
BLD-Framing/Rough-in | 5/10/2019 | 5/13/2019 | 5/13/2019 | A | PART |
Tony Young
|
|
|
Phone #: ###-#### Inspection requested via web by Steve Hanson,, correction notice posted,, house only
|
BLD-Wall Bracing | 4/30/2019 | 4/30/2019 | 4/30/2019 | P | PASS |
Tony Young
|
|
|
Phone #: ###-#### Inspection requested via web by Steve Hanson,, garage ok
|
BLD-Wall Bracing | 4/16/2019 | 4/16/2019 | 4/16/2019 | P | PASS |
Brandon Shaw
|
|
|
Phone #: ###-#### Inspection requested via web by Steve Hanson
|
BLD-Foundation | 3/26/2019 | 3/26/2019 | 3/26/2019 | A | PART |
Tony Young
|
|
|
Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro,, garage walls,, work in progress
|
BLD-Footing | 3/22/2019 | 3/22/2019 | 3/22/2019 | A | PART |
Tony Young
|
|
|
As late as possible Phone #: 2088708888 >> Inspection requested via mobile web by Wes,, garage footings ok
|
BLD-Foundation | 3/8/2019 | 3/8/2019 | 3/8/2019 | A | PASS |
Dave Hannah
|
|
|
As late as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro
|
BLD-Footing | 3/7/2019 | 3/7/2019 | 3/7/2019 | P | PART |
Tony Young
|
|
|
As early as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro ,, grade footings on north side,, will need compaction reports and means to have the footing below grade on the west side
|
BLD-Foundation | 2/18/2019 | 2/19/2019 | 2/19/2019 | A | PART |
Tony Young
|
|
|
As early as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro.. basement wall,, work in progress,, also planter
|
BLD-Footing | 2/6/2019 | 2/6/2019 | 2/6/2019 | P | PART |
Tony Young
|
|
|
Wes Phone #: ###-####,, basement footing,, work in progress,, needs to be 12" thick
|