Permit Information
Permit NumberBLD18-04352
StatusFinaled
Name ALTENERGY INC
Site Address 4782 S SPOTTED HORSE AVE
Project NameBlair 5.89kW Solar
Customer Number 
ePlanReviewYes
Description
Altenergy will be installing a 337 sq. ft., single array, 5.89 kW solar Photovoltaic system using (19) Silfab 310 W All Black Monocrystalline PV modules with Enphase IQ7 Microinverters installed beneath each module flush on the South facing roof of the Blair home. Modules will be wired to microinverters mounted to each panel such that there will be one string of 10 and one string of 9 modules/microinverters. The AC circuit will be run internally in the attic or externally on the roof in metallic conduit to the combiner panel mounted outside on the garage wall next to the electrical main panel. The AC power from the combiner panel will run to a dedicated utility disconnect grouped with the electric service meter and inverter and then into the main electrical panel to make a load-side connection via a back-fed breaker. Array does not exceed 33 percent of total roof. All work per plans, manufacturers specs and local code. ***RDP***
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Aging Inspection10/21/201910/21/201910/21/2019 DONE
DetailsBrandon Shaw
DOC - Permit Finaled10/21/201910/21/201910/21/2019PPASS
DetailsBrandon Shaw