Permit NumberBLD19-00376
StatusFinaled
Name LEVCO BUILDERS LLC
Site Address 1620 S HILTON ST
Project NameGarcia Addition
Customer Number 
ePlanReviewNo
Description
CAT I Hillside Addition. Permit for a remodel, to include: converting 341 sq. ft. garage into dining area with pantry and addition of 138 sq. ft. half bath and laundry room. Removing existing brick walls of garage and reframing as 2x6 - reusing brick at front of addition to match house. Removing walls at kitchen. Adding doors out to existing deck. - All work per plans, notations, attachments, engineering, local codes & ordinances. Separate electrical, plumbing & mechanical permits required. JJN
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at 208-608-7168 with questions.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final2/7/20202/7/20202/7/2020PPASS
DetailsTell Riley
jack Phone #: ###-####//final complete per approved plans//smoke and CO detectors added//
DOC - Permit Finaled2/7/20202/7/20202/7/2020PPASS
DetailsTell Riley
BLD-Final1/23/20201/24/20201/24/2020AFAIL
DetailsTell Riley
Joe Phone #: ###-####//need to add smoke and combo detectors to code//need city approved plans onsite//called contractor and let him know//
BLD-Aging Inspection10/29/201910/29/201910/29/2019 PASS
DetailsTell Riley
Expires: 12/14/19
BLD-Energy code compliance6/14/20196/17/20196/17/2019APASS
DetailsTell Riley
Josh Phone #: ###-####//ok to cover framing//
BLD-Framing/Rough-in6/12/20196/12/20196/12/2019PPASS
DetailsTell Riley
Framing ok per plans//call for energy
BLD-Energy code compliance6/11/20196/12/20196/12/2019PNR
DetailsTell Riley
Josh Phone #: ###-####//needs Mechanical rough in inspection//call in for framing/rough-in inspection once mechanical has passed// left message on number provided.//
BLD-Framing/Rough-in5/2/20195/3/20195/3/2019ACANC
DetailsMike Jordan
Josh Phone #: ###-####
BLD-Wall Bracing5/3/20195/3/20195/3/2019APASS
DetailsMike Jordan
Josh Phone #: ###-####
BLD-Foundation3/14/20193/15/20193/15/2019APASS
DetailsJim Sly
Willy Phone #: ###-####
BLD-Footing3/12/20193/12/20193/13/2019PPASS
DetailsJim Sly
Joe Phone #: ###-####
BLD-Footing3/11/20193/11/20193/12/2019PNR
DetailsJim Sly
Willie Phone #: ###-####
Need approval from Public Works.