Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberBLD19-00664
StatusIssued
Name GUHO CORP
Site Address 780 W MAIN ST
Project NameCapitol Terrace 2nd Flr Shell
Customer Number 
ePlanReviewYes
Description
(VANILLA – CAPTIAL TERRACE BUILDING - 2ND FLOOR) NO OCCUPANCY ALLOWED UNDER THIS PERMIT. TENANT SHALL APPLY FOR CERTIFICATE OF OCCUPANCY PRIOR TO OCCUPYING THE SPACE. Permit is to perform interior remodel work on the 2nd floor at the southwest portion of the building. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of select non-bearing interior partition walls, removal of select door/door frames, removal of select existing handrails, removal of select floor finish, removal of select FRP paneling, select new structural slab floor infill with underside sprayed fire-resistant materials on the structural supports, select new interior nonbearing wall partitions, select new rated shaft wall, select new door/door frame, electrical work, plumbing work, mechanical work and interior finishes in compliance with Ch. 8 of the current IBC. Note: special inspection required, see attached 310 form. Note 2: Per outsource engineering beam sizes are not called out at shaft infill area, but assumed to be same as at stair infill since same details are used. This building is fully Fire Sprinklered. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/23/20199/24/20199/25/2019APASS
DetailsDave Hannah
Tom Phone #: ###-####
FIRE-Final Inspection9/19/20199/19/20199/19/2019PPASS
DetailsJim Page
No fire sprinkler modifications per this scope, no fire alarm modifications, per this scope, fire extinguishers are in common areas with current inspection tags. Final life fire safety inspection for scope of work complete, signature not provided due to no signature card.

TOM Phone #: ###-####
BLD-Other4/30/20194/30/20194/30/2019PPASS
DetailsDave Hannah
fire proofing // Tom Phone #: ###-####
FIRE-Final Inspection4/29/20194/30/20194/30/2019ACANC
DetailsMark Scharfen
Wrong permit called in. Fire safeing, not life safety. Cancelled.

Tom Phone #: ###-####
BLD-Foundation4/24/20194/25/20194/26/2019APASS
DetailsDave Hannah
rebar // Tom Phone #: ###-#### floor infill at stairs ok
BLD-Framing/Rough-in4/23/20194/23/20194/25/2019PPART
DetailsDave Hannah
Tom- shaft wall inspection Phone #: ###-####
BLD-Framing/Rough-in4/22/20194/22/20194/22/2019PPART
DetailsTony Young
Tom Phone #: ###-####,, upper 2' extension ok to cover,, ?s on shaft design,, needs to be per UL listing,, or get a fix from architect
BLD-Framing/Rough-in4/8/20194/9/20194/9/2019APASS
DetailsDave Hannah
Tom Phone #: ###-####