Permit Information
Permit NumberBLD19-00964
StatusUnder Review
Name KAILI WORTH
Site Address 706 N HAINES ST
Project Name706 N Haines
Customer Number 
ePlanReviewYes
Description
*** 06/25 PLAN MODIFICATION to add small 1-2-foot retaining walls added east of the home and along the north side of the home. A sidewalk was added along the south property line and some additional retaining walls (that create a planter) added west of the sidewalk out to the street*** Permit for the construction of a new 2234 sq. ft., one story single family dwelling with 3 bedrooms, 2.5 bathrooms and a 1131 sq. ft. attached garage per the approved plans and any notations. Prescriptive Energy Compliance. R-1C zoning and setbacks per planning. ***RDP***A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at 208-608-7168 with questions.

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Melissa Jannusch at 208-608-7168.

The final inspection of the site grading and drainage work shall be done by the design engineer. Written approval shall be submitted to Boise Public Works prior to the issuance of the building final.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/1/20205/4/20205/4/2020APEND
DetailsMike Jordan
Richard Phone #: ###-####. Will be ok for final once public works signs off.
BLD-Final4/23/20204/24/20204/28/2020PNR
DetailsDave Hannah
screened // Richard Phone #: ###-#### needs hill side sign offs
BLD-Energy code compliance11/14/201911/15/201911/15/2019APASS
DetailsDave Hannah
Jace Phone #: ###-####
BLD-Framing/Rough-in11/8/201911/8/201911/8/2019PPASS
DetailsDave Hannah
Dustin Phone #: ###-####
BLD-Framing/Rough-in11/5/201911/5/201911/6/2019PNR
DetailsDave Hannah
Justin Phone #: ###-#### needs air seal
BLD-Wall Bracing10/16/201910/17/201910/17/2019APART
DetailsTell Riley
shear // dustin Phone #: ###-####//ok to cover main house areas//garage front needs added holddowns per plans--have designer provide alternate for post installed anchors in place of cast in place hold downs speced on plans//
BLD-Footing8/30/20198/30/20198/30/2019PPASS
DetailsBrandon Shaw
Dustin Phone #: ###-####
BLD-Footing8/26/20198/26/20198/26/2019PNR
DetailsDave Hannah
Dustin Phone #: ###-#### needs geo tec on soils
BLD-Foundation7/25/20197/25/20197/25/2019PPASS
DetailsDave Hannah
As early as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro
BLD-Footing7/18/20197/19/20197/19/2019APART
DetailsMike Jordan
Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro
BLD-Footing7/18/20197/19/20197/18/2019ACANC
DetailsDave Hannah
As late as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro
BLD-Footing7/18/20197/18/20197/18/2019PNR
DetailsDave Hannah
As late as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro