Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberBLD19-01077
StatusFinaled
Name STRAIGHT LINE BUILDING SOLUTIONS LL
Site Address 12592 W EXPLORER DR Unit: 200
Project NameCarollo Engineers 2nd floor
Customer Number 
ePlanReviewYes
Description
(CAROLLO ENGINEERS – ALTA BUILDING – 2ND FLOOR) Permit is to remodel an existing 9,751 sq. ft. business space on the second floor within the existing two story building. Approval is contingent upon adhering to the approved plans on file and attached engineering. Work to include: removal of select interior nonbearing walls, removal of select door/door frames, construction of interior non-bearing walls to create (4) offices, an electrical room and a copy room, new folding partition wall system at the existing conference rooms, select new door/door frames, millwork, electrical work and interior finishes in compliance with Ch. 8 of the current IBC. This building is fully fire sprinklered for area increase. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
DOC - Permit Finaled  9/18/2019 DONE
passed final inspection 9-17-19
BLD-Final9/16/20199/17/20199/17/2019PPASS
DetailsTell Riley
Please call 30 mins ahead of time so I can meet you there. Phone #: ###-#### Inspection requested via web by Gerome Fries//final complete per plans//
FIRE-Final Inspection9/16/20199/17/20199/17/2019APASS
DetailsTroy Cobbley
life safety passed. Card signed.

Please call 30 mins ahead of time so I can meet you there. Phone #: ###-#### Inspection requested via web by Gerome Fries
FIRE-Final Inspection9/16/20199/16/20199/16/2019PCANC
DetailsTroy Cobbley
Please call 30 mins ahead of time so I can meet you there. Phone #: ###-#### >> Inspection requested via web by Gerome Fries Inspection cancelled from web by: Gerome Fries
FIRE-Final Inspection9/14/20199/16/20199/16/2019APART
DetailsMike Jordan
Please call 30 mins ahead so I can meet you there. Phone #: ###-#### Inspection requested via web by Gerome Fries. Fire/life safety will be ok for perm. as soon as the project related fire sprinkler permit has been finaled.
BLD-Final9/14/20199/16/20199/16/2019PCANC
DetailsTell Riley
Please call 30 mins ahead of time so I can meet you there. Phone #: ###-#### >> Inspection requested via web by Gerome Fries Inspection cancelled from web by: Gerome Fries
BLD-Final9/13/20199/16/20199/14/2019ACANC
DetailsTell Riley
Please call 3 mins head of time so I can meet you there. Phone #: ###-#### >> Inspection requested via web by Gerome Fries Inspection cancelled from web by: Gerome Fries
BLD-Ceiling Grid Inspection8/29/20198/30/20198/30/2019PPASS
DetailsMike Jordan
Please call 30 mins ahead of arrival. Phone #: ###-#### Inspection requested via web by Gerome Fries
BLD-Framing/Rough-in8/16/20198/19/20198/19/2019PPASS
DetailsTell Riley
Please call 30 min in ahead of time so I can meet you there. Phone #: ###-#### Inspection requested via web by Gerome Fries//wall cover for partitions in office area//ok to cover walls only//call for grid inspection//
BLD-Final7/18/20197/18/20197/18/2019PPART
DetailsTell Riley
Please call 30 minutes ahead Phone #: ###-#### Inspection requested via web by Gerome Fries//temp occupancy approved for phase 1 minor remodel//life safety and electrical have passed in this area//no temp occupancy signature area on card//
FIRE-Final Inspection7/17/20197/17/20197/18/2019PPART
DetailsTroy Cobbley
Life safety passed for the south side tennt space of the remodel work.

Phone #: ###-#### Inspection requested via web by Gerome Fries
BLD-Final7/12/20197/17/20197/17/2019ANR
DetailsMike Jordan
Please call 30 mins ahead of time Phone #: ###-#### Inspection requested via web by Gerome Fries. Fire final has failed.
FIRE-Final Inspection7/12/20197/16/20197/16/2019PFAIL
DetailsTroy Cobbley
Inspection was just for the south half of the second floor at this time. Basically all exit signs need repaired and emergency lighting provided in the remodeled tenant space and in the paths of egress down both stair wells and out of the building. All other items for this phase of the work appear ok.

Please call 30 mins ahead of time Phone #: ###-#### Inspection requested via web by Gerome Fries
BLD-Ceiling Grid Inspection6/26/20196/26/20196/26/2019APART
DetailsTell Riley
Please call 30 mins ahead of time so I can meet you there. Phone #: ###-#### Inspection requested via web by Gerome Fries//grid ok//need to get mechanical completed and inspected//do not cover until HVAC is passed//divider wall framing ok per engineering.//
BLD-Framing/Rough-in5/31/20196/3/20196/3/2019PPASS
DetailsMike Jordan
Please call 30 mins ahead of time so I can meet you there. Phone #: ###-#### Inspection requested via web by Gerome Fries. Interior steel stud framed walls only for phase 1. Will need inspection and engineering for folding wall system when installed.