BLD-Final | 12/3/2019 | 12/5/2019 | 12/5/2019 | A | PASS |
Brandon Shaw
|
|
|
garage key code 3283 Phone #: ###-#### Inspection requested via web by David Wipper
|
DOC - Permit Finaled | 12/5/2019 | 12/5/2019 | 12/5/2019 | P | PASS |
Brandon Shaw
|
|
|
|
BLD-Blower Door Test Results | 12/5/2019 | 12/5/2019 | 12/5/2019 | A | DONE |
Brandon Shaw
|
|
|
ACH50- 3.33
|
BLD-Other | 10/10/2019 | 10/10/2019 | 10/10/2019 | P | PASS |
Brandon Shaw
|
|
|
Larry- soffit inspection Phone #: ###-####
|
BLD-Other | 9/26/2019 | 9/26/2019 | 9/26/2019 | P | FAIL |
Brandon Shaw
|
|
|
As per plans- 5/8 type X and hardyboard to be used at all soffits and under front deck...
|
BLD-Energy code compliance | 9/17/2019 | 9/18/2019 | 9/18/2019 | P | PASS |
Brandon Shaw
|
|
|
See FIR19-00506 for sprinkler cover approval... Ok to cover...
|
BLD-Framing/Rough-in | 9/13/2019 | 9/16/2019 | 9/16/2019 | P | PEND |
Brandon Shaw
|
|
|
Corrections are SAT... OK to insulate, Pending Fire Sprinkler Pressure re-test...
|
BLD-Framing/Rough-in | 9/11/2019 | 9/12/2019 | 9/12/2019 | P | FAIL |
Brandon Shaw
|
|
|
Per plans- 6x6 DF #1 posts to bear down to foundation, supporting glue lam at garage... Per shear inspections walk thru, #3 shear walls to be blocked... Per plans- Stairway header to be (2)1.75x 18" LvL Provide Engineering for as built... Per plans- 2x Ledger to be attached with (2) 1/4x 4 1/2" SDS screws...
|
BLD-Wall Bracing | 8/23/2019 | 8/26/2019 | 8/26/2019 | A | PASS |
Brandon Shaw
|
|
|
Larry Phone #: ###-####
|
BLD-Foundation | 7/2/2019 | 7/3/2019 | 7/3/2019 | A | PASS |
Brandon Shaw
|
|
|
Work in progress...
|
BLD-Footing | 6/25/2019 | 6/25/2019 | 6/25/2019 | P | PART |
Tony Young
|
|
|
Late inspection will be good. want to pour in the morning Phone #: ###-#### Inspection requested via web by Ben Sears,, work in progress,, ok
|