Permit Information
Permit NumberBLD19-01123
StatusFinaled
Name BRIGHT STAR ENERGY MANAGEMENT LLC
Site Address 2638 W BEDFORD LN
Project NameSierra Vista Condos
Customer Number 
ePlanReviewYes
Description
(DWELLING UNIT – SIERRA VISTA CONDOMINIUMS – BUILDING F – FORMER RECREATION ROOM AND SALES OFFICE) (DRH18-00398) (CUP18-00039) The NFPA 13-R fire sprinkler system is used for occupancy. To convert a former recreation room and sales office to a 497 square foot 1 bedroom dwelling unit located at grade. The existing common use laundry room will be reduced in size by about 10 square feet to a floor area of about 141 square feet with a door directly to the outside. After the conversion, this building will have 5 dwelling units (3 on the first story and 2 on the second story) and a common use laundry room. This dwelling unit is not required to comply as a Type B dwelling unit. A fire sprinkler system will be installed throughout “Building F” in conjunction with this permit. Work is to include an 8 square foot 1-hr fire sprinkler riser room with a door directly to the outside, 1-hr dwelling unit separation walls extending from the floor to the underside of the roof deck to entirely separate this dwelling unit from the rest of the building, a new exterior window with a new structural header (2 - 2” x 6”) at the kitchen, a new window to replace an existing door, interior nonbearing walls, a dwelling unit kitchen, a dwelling unit toilet / bathing room, millwork, and finishes. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. An NFPA 13-R fire sprinkler system, as regulated by the Fire Department, will be installed throughout this building. A separate fire sprinkler permit shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final3/26/20203/27/20203/27/2020PPASS
DetailsJim Storey
Please call 30 minutes before hand for access to fire riser room. Phone #: ###-#### Inspection requested via web by Stephen Griswold
DOC - Permit Finaled3/27/20203/27/20203/27/2020PPASS
DetailsJim Storey
FIRE-Final Inspection3/25/20203/26/20203/26/2020APASS
DetailsTroy Cobbley
Life safety passed. Call for access/site meeting. Phone #: ###-#### Inspection requested via web by Stephen Griswold
FIRE-Final Inspection3/25/20203/25/20203/25/2020PFAIL
DetailsTroy Cobbley
Need city approved plans an dsmall documents, need smoke alarms placed and tested as discussed, need fire extinguisher placed as discussed. Need address as discussed.

NEED FINAL LIFE SAFETY COMPLETED; WAS NOT DONE DURING INITIAL FIRE FINAL INSPECTION Phone #: ###-#### Inspection requested via web by Stephen Griswold
BLD-Final3/24/20203/24/20203/24/2020PCANC
DetailsJim Storey
Please call prior to inspection to coordinate access. Phone #: ###-#### >> Inspection requested via web by Stephen Griswold Inspection cancelled from web by: Stephen Griswold
BLD-Final1/3/20201/3/20201/3/2020PFAIL
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Stephen Griswold need fire and hvac finals
FIRE-Final Inspection1/3/20201/3/20201/3/2020PCANC
DetailsTroy Cobbley
Need fire alarm and sprinkler permits addressed as per discussion before life safety inspection can be completed.

Phone #: ###-#### Inspection requested via web by Stephen Griswold
BLD-Framing/Rough-in9/30/20199/30/20199/30/2019PPART
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Stephen Griswold INSP-Sprinkler Rough-in 9/26/2019 9/27/2019 9/27/2019 P PART





DetailsTroy Cobbley

Tenting failed for all areas. No piping to be covered. Rough-in passed for the single level area of work but again no piping can be covered. Also prior to a final inspection R38 insulation value will need to be provided.
framing ok to cover upon passing fire insp.
BLD-Framing/Rough-in9/5/20199/5/20199/5/2019PFAIL
DetailsJim Storey
need fire chakl per plan/ need hvac permit and insp./ fire spk insp// group all permits to bld.
BLD-Framing/Rough-in9/4/20199/4/20199/4/2019PNR
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Stephen Griswold
BLD-Framing/Rough-in8/6/20198/6/20198/6/2019PFAIL
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Stephen Griswold c/n arch to address conf with builder.