Permit Information
Permit NumberBLD19-01233
StatusFinaled
Name CM COMPANY
Site Address 7009 W FRANKLIN RD
Project NameBishop Kelly High Kitchen
Customer Number 
ePlanReviewYes
Description
(BISHOP KELLY HIGH SCHOOL KITCHEN REMODEL) // 09/20/19 PLAN MOD TO REMOVE ALTERNATE #1 FROM PLANS. ACCESSIBLE UPGRADES TO SINGLE USER RESTROOM WILL BE COMPLETED IN PHASE II UNDER FUTURE PERMIT, BY 10/02/2020. SEE ATTACHED LETTER. JAR // Permit to remodel existing kitchen. Work to include: relocating cookline and hood; adding sinks; new walk in cooler and freezer; structural bracing to support new openings in masonry wall and roof top units; new lighting and power; mechanical work including new roof top units; plumbing; and new interior finishes in compliance with Ch. 8 of the 2015 IBC. Permit drawings include Bid Alternate #1. If this alternate is not accepted, revised drawings need to be submitted as a Plan Modification with Alternate #1 removed from plans. This is a scope of work permit only with a certificate of completion to be issued upon completion and approval of the project. This building is fully Fire Sprinklered for area increase and E occupancy with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JAR**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final10/18/201910/21/201910/21/2019APASS
DetailsMike Jordan
Can we please final our life fire safety now that the FA permit FIR19-00585 is finaled (revised drawings approved). Thank you. Phone #: ###-#### Inspection requested via web by Jackie Phelps
DOC - Permit Finaled10/21/201910/21/201910/21/2019PPASS
DetailsMike Jordan
FIRE-Final Inspection10/18/201910/21/201910/21/2019APASS
DetailsTroy Cobbley
Life safety passed. Thank you. Phone #: ###-#### Inspection requested via web by Jackie Phelps
FIRE-Final Inspection10/11/201910/15/201910/15/2019APART
DetailsTroy Cobbley
A temp for life safety is being given until the as-builts/plan mods are approved.

Thank you. Phone #: ###-#### Inspection requested via web by Jackie Phelps
FIRE-Alarm Testing10/11/201910/15/201910/15/2019ADONE
DetailsTroy Cobbley
See the project related fire alarm permit for specifics for the fire alarm testing.
BLD-Final10/11/201910/15/201910/15/2019APART
DetailsMike Jordan
Fire Alarm / Final inspections scheduled for 7 am Tuesday. Please come afterward. Thank you. Phone #: ###-#### Inspection requested via web by Jackie Phelps. OK for temp occ. Will be ok for perm occ. once fire signs perm.
BLD-Final10/11/201910/16/201910/11/2019ACANC
DetailsMike Jordan
Fire Alarm / Fire Final inspection scheduled for 7 AM Tuesday. Please come afterward. Thank you. Phone #: ###-#### >> Inspection requested via web by Jackie Phelps Inspection cancelled from web by: Jackie Phelps
FIRE-Final Inspection10/11/201910/16/201910/11/2019ACANC
DetailsTroy Cobbley
Please come first thing (7 am) so we can get done before school starts. We cant sound alarm when school in session. Thank you. Phone #: ###-#### >> Inspection requested via web by Jackie Phelps Inspection cancelled from web by: Jackie Phelps
FIRE-Alarm Testing10/11/201910/14/201910/11/2019ACANC
DetailsTroy Cobbley
Preferably before school opens if plan review is completed. Phone #: ###-#### >> Inspection requested via web by Jimmie Miller Inspection cancelled from web by: Jackie Phelps
BLD-Final10/11/201910/14/201910/11/2019PCANC
DetailsMike Jordan
Preferably before school opens if plan review is completed. Phone #: ###-#### >> Inspection requested via web by Jimmie Miller Inspection cancelled from web by: Jackie Phelps
FIRE-Final Inspection10/11/201910/14/201910/11/2019ACANC
DetailsTroy Cobbley
Preferably before school opens if plan review is completed. Phone #: ###-#### >> Inspection requested via web by Jimmie Miller Inspection cancelled from web by: Jackie Phelps
BLD-Final10/10/201910/11/201910/11/2019PCANC
DetailsBrandon Shaw
Preferably right after final life safety. Phone #: ###-#### Inspection requested via web by Jimmie Miller
FIRE-Final Inspection10/10/201910/11/201910/11/2019ANR
DetailsTroy Cobbley
No ready for life safety due to fire alarm resubmittal. Phone #: ###-#### Inspection requested via web by Jimmie Miller
BLD-Framing/Rough-in9/10/20199/11/20199/11/2019APASS
DetailsTell Riley
jimmie//SSC clips installed per RFI 027 for connection of box header//correction made per Mikes notes//
BLD-Framing/Rough-in9/5/20199/6/20199/6/2019APART
DetailsMike Jordan
Early as possible please. Phone #: ###-#### Inspection requested via web by Jimmie Miller. Steel stud framing and box headers for new openings. Needs to install SSC clips from bottom track to each stud. Contractor to fllow up with RFI approving the angle clips in leiu of HUC hangars for box header to jamb conections.
BLD-Framing/Rough-in9/5/20199/5/20199/5/2019PNR
DetailsJim Storey
Jimmy Phone #: ###-#### no one on site.
BLD-Wall cover8/22/20198/22/20198/22/2019PCANC
DetailsMike Jordan
Ross is on site contact through 8/27. ###-####. We are scheduled to sheetrock the ceiling tomorrow, insulation has been removed and replaced with new. RFI mentioned in early inspection comment has been sent. Please confirm If we need a re-inspection prior to cover. Thank you! Jackie Phelps ###-#### Phone #: ###-#### >> Inspection requested via web by Jackie Phelps Inspection cancelled from web by: Jackie Phelps
BLD-Framing/Rough-in8/16/20198/16/20198/16/2019PPASS
DetailsMike Jordan
Jimmy Phone #: ###-####. Interior steel stud furred walls for equipment chases. Also reviewed RFI for use of A35's.
BLD-Framing/Rough-in8/5/20198/5/20198/5/2019PPART
DetailsMike Jordan
Jimmie Phone #: ###-####. Additional 2x12 joist sistering to support new mech. equpment in kitchen. Need RFI for alternate attacment of A35 in lieu of the 2 inch bearing.