BLD-Aging Inspection | 8/5/2020 | 8/5/2020 | 8/6/2020 | | PEND |
Tell Riley
|
|
|
no final inspections requested//
|
BLD-Aging Inspection | 8/4/2020 | 8/4/2020 | 8/5/2020 | | PEND |
Tell Riley
|
|
|
|
BLD-Framing/Rough-in | 3/23/2020 | 3/23/2020 | 3/23/2020 | P | PASS |
Tell Riley
|
|
|
Framing Inspection. Please contact us 20 minutes prior to have someone on site. Thank you! Phone #: ###-#### Inspection requested via web by Oleksiy Yanchuk//email from engineer recieved//corrections made//
|
BLD-Framing/Rough-in | 3/9/2020 | 3/10/2020 | 3/10/2020 | A | FAIL |
Tell Riley
|
|
|
Correction List: Nailed all green plate with hand dipped galvanized nails. Removed 3 small panels of shear to make visible the hold downs Added Simpson S27 straps on the portal header. A roof plan and engineering is in the fireplace. Phone #: ###-#### Inspection requested via web by Oleksiy Yanchuk//correction notice posted/need two hold downs per portal frame- only 1 per side on side portal frames//straps are not the same as specified on plans, and all 4 wall need them per the engineering// trusses ok//fix framing per plans or have enginneer approve//
|
BLD-Framing/Rough-in | 3/6/2020 | 3/9/2020 | 3/9/2020 | A | FAIL |
Tell Riley
|
|
|
Shear wall and Framing inspection Approved plans are on site in the fire place. Phone #: ###-#### Inspection requested via web by Oleksiy Yanchuk//CN posted//need hot dip galvanized nails in pt//need access to columns to verify attachments per plans//straps need added opposite side of sheating on all portal frame per details on plans//need truss plans//
|
BLD-Foundation | 11/18/2019 | 11/18/2019 | 11/18/2019 | A | PASS |
Tell Riley
|
|
|
Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro//WIP...pending specials if required on this portion//
|
BLD-Foundation | 11/15/2019 | 11/15/2019 | 11/15/2019 | P | CANC |
Tell Riley
|
|
|
Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro//cancel per Alvaro//
|
BLD-Footing | 11/14/2019 | 11/14/2019 | 11/14/2019 | P | PART |
Tell Riley
|
|
|
As early as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro//cabana and planter footings--ok per plans//pending specials if required//setbacks surveyed in and per plans//
|
BLD-Foundation | 10/24/2019 | 10/24/2019 | 10/25/2019 | P | DEFR |
Tell Riley
|
|
|
Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro//defer to special inspection//spoke with contact and rebar, formwork and concrete testing will be performed//
|
BLD-Footing | 10/17/2019 | 10/17/2019 | 10/17/2019 | P | PASS |
Tell Riley
|
|
|
Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro//footings per plans//setbacks were set by surveyor//ok pending specials //
|
BLD-Footing | 10/16/2019 | 10/16/2019 | 10/16/2019 | P | FAIL |
Tell Riley
|
|
|
*please as late as possible after 3:30pm** Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro///need geotech report approved by public works prior to pouring footings//special inspections for rebar and concrete placement are required per plans//
|