Permit Information
Permit NumberBLD19-02563
StatusFinaled
Name PEAK CONSTRUCTION SERVICES LLC
Site Address 350 N MILWAUKEE ST Unit: 2016
Project NameSbarro - T.I. BTS #2016
Customer NumberEARLY START DEMO BLD19-02997
ePlanReviewYes
Description
(SBARRO - TENANT IMPROVEMENT - BTS #2016) **Permit for minor tenant improvements to an existing 1010 sq.ft. restaurant within a covered mall building. Work to include new ACT tiles, new lighting, new equipment, new countertops, refinishing existing millwork, and new finishes. Finishes to be in compliance with Ch. 8 of the 2015 IBC. This building is fully fire sprinkled with an approved fire alarm system. Any alterations or modifications to the buildings fire sprinkler or fire alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. The smoke evacuation system shall remain operational as originally installed under the 1985 UBC. NOTE: a separate sign permit for interior mall signage is required before sign installation. MDH Approval of relocated Class 1 hood is only for use above the pizza oven. Hood would need to be re-evaluated for any other cooking equipment. Chad S.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
FIRE-Final Inspection11/6/201911/6/201911/6/2019PPASS
DetailsTroy Cobbley
life safety passsed.

Jason Phone #: ###-####
BLD-Final11/5/201911/5/201911/5/2019PPASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Jason Osterburg. Ok for prm occ.
BLD-Final10/8/201910/8/201910/8/2019APEND
DetailsBrandon Shaw
See Fire entry...
No other issues...
FIRE-Final Inspection10/8/201910/8/201910/8/2019APART
DetailsTroy Cobbley
A temp for life safety is being given until a fire alarm permit is issued/passed for the relocation of the smoke detector and deleting the monitor module for the demo'd hood suppression system.

Phone #: ###-#### Inspection requested via web by Jason Osterburg
FIRE-Alarm Testing10/8/201910/8/201910/8/2019APASS
DetailsTroy Cobbley
The smoke evac system passed. Phone #: ###-#### Inspection requested via web by Jason Osterburg
BLD-Final10/3/201910/4/201910/4/2019ANR
DetailsMike Jordan
Joe Phone #: ###-####
FIRE-Final Inspection10/3/201910/4/201910/4/2019AFAIL
DetailsTroy Cobbley
Provide permit to relocate the smoke detector and delete the monitor module for the suppression system that is being deleted, provide permit to demo the hood suppression system, provide fire extinguisher as discussed, test the smoke evac system,

Joe Phone #: ###-####
BLD-Ceiling Grid Inspection9/27/20199/27/20199/27/2019PPEND
DetailsBrandon Shaw
Pend Ele cover appoval...
OK to cover perimeter...
BLD-Framing/Rough-in9/5/20199/6/20199/6/2019APASS
DetailsMike Jordan
Jason Phone #: ###-####. Interior steel stud framed walls ok. Noted that type 1 hood is supported from bottom chord of I joist. Contractor to provide engineering showing I joist can support additional weight from bottom chords or support from top chords.
BLD-Framing/Rough-in8/19/20198/19/20198/19/2019PPASS
DetailsMike Jordan
Jason Phone #: ###-####. Interior steel stud framed walls ok, pending elec. and plumbing rough in inspections. ok to one side at type 1 hood only.