Permit Information
Permit NumberBLD19-02619
StatusTemporary Occupancy
Name PERRYMAN CONSTRUCTION MANAGEMENT IN
Site Address 7482 N LUCY ROSE LN
Project NameEaglehawk Fourplex - Bldg 3
Customer NumberBLD19-02617 TO BLD19-02622
ePlanReviewNo
Description
(EAGLEHAWK FOURPLEX MULTIFAMILY APARTMENTS – 7482 N. LUCY ROSE ST. – BUILDING 3) (6 BUILDING PERMITS UNDER BLD19-02617 IN EPLAN) //2-12-2020 PLAN MODIFICATION TO REPLACE MECHANICAL DESIGN WITH MANUAL S, J, ADJUSTMENTS TO MECHANICAL EQUIPMENT AND DUCTWORK. Jg.// Permit for the construction of a 4,852 sq. ft. 2-story four-unit apartment building. This building is one of six buildings within a multi-family development. Work to include general site work and the construction of the new building per the approved plans attached engineering and plan review report. Note: Special Inspections Required see form 310. This building is to be fully fire sprinklered with an NFPA 13-R system as required for residential occupancy. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/22/20206/23/20206/23/2020PPASS
DetailsTony Young
Phone #: ###-#### Inspection requested via web by bill gullickson/ ok pending zoning and others
FIRE-Final Inspection6/22/20206/23/20206/23/2020PPASS
DetailsJim Page
Previously noted items have been corrected, final life fire safety inspection is complete, signature card not available at time of inspection.

Phone #: ###-#### Inspection requested via web by bill gullickson
BLD-Final6/17/20206/18/20206/23/2020PNR
DetailsTony Young
please call 30 minutes before inspection Phone #: ###-#### Inspection requested via web by bill gullickson
FIRE-Final Inspection6/17/20206/18/20206/18/2020PFAIL
DetailsJim Page
Riser room is not 1 hour rated as required under BMC 7-01-51. Provide apartment numbers instead of apartment letters as specified under the Building Permit Fire Code Review Comments section 12A. Hard wire riser room heaters instead of plug in as discussed.

please call 30 minutes before inspection Phone #: ###-#### Inspection requested via web by bill gullickson
BLD-Wall Bracing4/1/20204/2/20204/2/2020APASS
DetailsTony Young
Phone #: ###-#### Inspection requested via web by bill gullickson,, exterior ok to cover
BLD-Wall Bracing3/25/20203/26/20203/26/2020APEND
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by bill gullickson. Needs to resolve with Tony.
BLD-Energy code compliance3/20/20203/20/20203/20/2020PPASS
DetailsTell Riley
Insulation inspection. Please call Nic a half hour before inspection. Thanks, Phone #: ###-#### Inspection requested via web by Nic Van Diepen//contactor stated the washer boxes would be switched out for rated boxes in 1 hour wall//insulation ok//
BLD-Energy code compliance3/17/20203/18/20203/18/2020APASS
DetailsDave Hannah
Airseal inspection. Please call Nic a half hour before inspection. Thanks, Phone #: ###-#### Inspection requested via web by Nic Van Diepen
BLD-Framing/Rough-in3/17/20203/18/20203/18/2020APASS
DetailsDave Hannah
Framing inspection. Please call Nic a half hour before inspection. Thanks, Phone #: ###-#### Inspection requested via web by Nic Van Diepen
BLD-Energy code compliance3/11/20203/12/20203/12/2020ANR
DetailsJim Storey
Airseal Inspection. Please call Ed a half hour before inspection. ###-####. Thanks, Phone #: ###-#### Inspection requested via web by Nic Van Diepen
BLD-Framing/Rough-in3/11/20203/12/20203/12/2020ANR
DetailsJim Storey
Please call Ed a half hour before inspection. ###-####. Thanks, Phone #: ###-#### Inspection requested via web by Nic Van Diepen
BLD-Wall Bracing2/14/20202/18/20202/18/2020ACANC
DetailsTony Young
Ed Phone #: ###-#### Inspection cancelled from web by: Nic Van Diepen
BLD-Wall cover1/31/20201/31/20201/31/2020PPASS
DetailsTony Young
Exterior walls shear inspection. Please call Ronald when on the way, he will have approved plans for both lots 9;2 - Ronald - ###-####. Thanks, Phone #: ###-#### Inspection requested via web by Nic Van Diepen
BLD-Concrete12/13/201912/13/201912/13/2019APASS
DetailsTony Young
Building interior slab on grade. Concrete at 9:30am. Phone #: ###-#### Inspection requested via web by Nic Van Diepen
BLD-Energy code compliance11/20/201911/20/201911/20/2019PPASS
DetailsTony Young
Foundation insulation inspection. Please call Nic on way to inspection. Thanks, Phone #: ###-#### Inspection requested via web by Nic Van Diepen
BLD-Foundation11/12/201911/12/201911/13/2019PDONE
DetailsTony Young
Pat- foundation wall inspection Phone #: ###-####
BLD-Foundation11/8/201911/12/201911/12/2019APART
DetailsTony Young
Pat- foundation wall inspection Phone #: ###-####/// footing ok
BLD-Footing11/7/201911/7/201911/8/2019PPASS
DetailsTony Young
Pat Phone #: ###-####
BLD-Footing11/5/201911/5/201911/6/2019PNR
DetailsTony Young
Chris Phone #: ###-####
BLD-Footing11/4/201911/4/201911/6/2019PNR
DetailsTony Young
Chris Phone #: ###-####