Permit Information
Permit NumberBLD19-02745
StatusFinaled
Name HHS CONSTRUCTION LLC
Site Address 2373 S TRAPPER PL
Project NameHarris North Lot 12 Block 1
Customer Number 
ePlanReviewYes
Description
**W.U.I. HILLSIDE ZONE A CLASS "A" ROOF AND NON-COMBUSTIBLE EXTERIOR SIDING REQUIRED** **PRESCRIPTIVE ENERGY REQUIREMENTS** Permit for the construction of a new 3192 sq. ft., one story single family dwelling with 4 bedrooms, 2.5 bathrooms, approximately 316 sq. ft. of covered patio/porch and a 824 sq. ft. attached garage per the approved plans and any notations. SP-01 zoning and setbacks per planning. JJN ***SPRINKLERS ARE NOT REQUIRED***LGM A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at 208-608-7168 with questions.

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Melissa Jannusch at 208-608-7168.

The final inspection of the site grading and drainage work shall be done by the design engineer. Written approval shall be submitted to Boise Public Works prior to the issuance of the building final.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/21/20201/21/20201/21/2020PPASS
DetailsBrandon Shaw
Les Phone #: ###-####
DOC - Permit Finaled1/21/20201/21/20201/21/2020PPASS
DetailsBrandon Shaw
BLD-Blower Door Test Results1/21/20201/21/20201/21/2020PDONE
DetailsBrandon Shaw
ACH50- 3.84
BLD-Blower Door Test Results1/21/20201/21/20201/21/2020PCANC
DetailsBrandon Shaw
Les Phone #: ###-####
BLD-Blower Door Test Results1/21/20201/21/20201/21/2020PCANC
DetailsBrandon Shaw
Les Phone #: ###-####
BLD-Energy code compliance10/24/201910/24/201910/24/2019PPASS
DetailsBrandon Shaw
Les Phone #: ###-####
BLD-Other10/22/201910/23/201910/23/2019APASS
DetailsBrandon Shaw
sofit // Les Phone #: ###-####
BLD-Framing/Rough-in10/22/201910/22/201910/22/2019PPASS
DetailsBrandon Shaw
Corrections SAT...
OK to insulate...
BLD-Framing/Rough-in10/15/201910/15/201910/15/2019PFAIL
DetailsBrandon Shaw
Provide an approved Engineer fix for A11 truss with 8' of missing bottom cord...
Per plans- (4) 2x6 needed ar corner point load- breakfast nook...
Per plans- (2) 2x10 called for at center window, breakfasr nook...
Verify (2) 9 1/2 LvL and LSTA24 straps are in place- see plans...
Verify BTM cord to DBL top plate with A34 anchors at 32" o.c....
BLD-Wall Bracing9/19/20199/20/20199/20/2019APASS
DetailsBrandon Shaw
Les Phone #: ###-####
BLD-Foundation8/30/20198/30/20198/30/2019APASS
DetailsBrandon Shaw
Work in progress...
BLD-Footing8/28/20198/28/20198/28/2019PPASS
DetailsBrandon Shaw
Work in progress...