Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberBLD19-02851
StatusIssued
Name ALTECCA LLC
Site Address 8648 W ELISA ST
Project NameBSR Equipment Storage Bldg
Customer Number 
ePlanReviewYes
Description
(BSR EQUIPMENT STORAGE BUILDING #2) Special inspections are required, see form #310 for details. This building is not fire sprinkled. Permit to construct a 6,160 sqft. pre-engineered metal pole building for use as a storage facility. Work to include: 5" reinforced concrete slab floor, reinforced concrete perimeter foundation, 2-hour fire wall at south elevation, loading ramp with guardrails, and 18' x 12' chain link garbage enclosure. Approval is contingent on adhering to the approved plans, structural engineering, notations, and local codes and ordinances. Racking exceeding 8'-0" requires a separate permit. MDH
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/30/20207/31/20207/31/2020APART
DetailsMike Jordan
Screened- please call before- Taylor Phone #: ###-####. Ok for temp occ. Guard at loading dock is not code compliant.
FIRE-Final Inspection7/30/20207/30/20207/30/2020PPASS
DetailsTroy Cobbley
life safety passed.

Screened- Taylor Phone #: ###-####
BLD-Wall cover6/19/20206/23/20206/23/2020PPASS
DetailsMike Jordan
screened // Taylor Phone #: ###-####
BLD-Wall cover6/5/20206/5/20206/5/2020PPASS
DetailsMike Jordan
fire wall .. call to meet // Taylor Phone #: ###-####
BLD-Concrete5/20/20205/21/20205/21/2020APASS
DetailsMike Jordan
rebar slab- late morning if poss- Taylor *screened* Phone #: ###-####
BLD-Footing5/8/20205/11/20205/11/2020APASS
DetailsMike Jordan
Tyalor *screened* Phone #: ###-####. Loading dock walls.
BLD-Footing5/7/20205/8/20205/8/2020APASS
DetailsMike Jordan
*screened* Alex Phone #: ###-####. Footings for loading dock ok.
BLD-Footing5/6/20205/7/20205/7/2020PNR
DetailsMike Jordan
Screened- please later in the AM call for more details-concrete schedule for 2pm- Taylor Phone #: ###-####
BLD-Foundation4/30/20205/1/20205/1/2020PPASS
DetailsMike Jordan
REBAR // Taylor Phone #: ###-####. Slab on grade rebar.
BLD-Footing4/29/20204/30/20204/30/2020APART
DetailsMike Jordan
Screened- Rebar inspection-Taylor Phone #: ###-####. West half, interior slab on grade.
BLD-Foundation4/20/20204/21/20204/21/2020APART
DetailsMike Jordan
rebar- pouring at 1:45-Taylor **Cleared** Phone #: ###-####. perimeter frost wall. Ok to place concrete pending special inspection.
BLD-Footing4/17/20204/20/20204/20/2020APASS
DetailsMike Jordan
screened pour at 1 // Taylor Phone #: ###-####. Column pedestals
BLD-Concrete4/16/20204/17/20204/17/2020APART
DetailsMike Jordan
screened // rebar - pouring at 1:45 // Taylor Phone #: ###-####. perimeter column pad footings. Work in progress on completed reinforcement. Ok to place conc. pending special inspection.
BLD-Conference4/9/20204/10/20204/10/2020ADONE
DetailsMike Jordan
screened // Tyler Phone #: ###-####