Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberBLD19-03384
StatusFinaled
Name PANORAMA CONSTRUCTION
Site Address 8025 W LEMHI ST
Project Name8025 W Lemhi
Customer Number 
ePlanReviewYes
Description
**PRESCRIPTIVE ENERGY REQUIREMENTS** Permit for the construction of a new 1120 sq. ft., one story single family dwelling with 3 bedrooms, 2 bathrooms, approximately 40 sq. ft. of covered patio/porch and a 440 sq. ft. attached garage per the approved plans and any notations. R-1C zoning and setbacks per planning. JJN
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final4/15/20204/15/20204/15/2020PPASS
DetailsMike Jordan
*screened* Call for access code - Jeff Phone #: ###-####
DOC - Permit Finaled4/15/20204/15/20204/15/2020PPASS
DetailsMike Jordan
BLD-Blower Door Test Results4/15/20204/15/20204/15/2020PDONE
DetailsMike Jordan
4.6
BLD-Energy code compliance12/24/201912/26/201912/26/2019PPASS
DetailsDave Hannah
Jeff Phone #: ###-####
BLD-Framing/Rough-in12/24/201912/26/201912/26/2019PPASS
DetailsDave Hannah
Jeff Phone #: ###-####
BLD-Energy code compliance12/23/201912/23/201912/23/2019PFAIL
DetailsMike Jordan
Jeff Phone #: ###-####
BLD-Framing/Rough-in12/23/201912/23/201912/23/2019PFAIL
DetailsMike Jordan
Jeff Phone #: ###-####. Complete lateral bracing on A06 truss. (missed bracing on last A06 truss) Needs to encapsulate insulation on all six sides at perimeter of vaulted ceiling. do not cover.
BLD-Framing/Rough-in12/19/201912/19/201912/19/2019PFAIL
DetailsMike Jordan
Jeff Phone #: ###-####. Complete lateral bracing on A03,A04,A05 and A06 trusses. Fireblock concealed space by shower/tub at ceiling. Provide strongbacks on both gable ends. provide 2x6 studs under top plate breaks in garage, both sides, (east and west)
BLD-Wall Bracing11/21/201911/21/201911/21/2019PPASS
DetailsMike Jordan
Jeff Phone #: ###-####
BLD-Footing11/4/201911/4/201911/4/2019PPASS
DetailsMike Jordan
pouring at 1:45 // James Phone #: ###-####