Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberBLD19-03490
StatusFinaled
Name HHS CONSTRUCTION LLC
Site Address 5916 E HOOTOWL DR
Project Namelot 3 block 2 harris north
Customer Number 
ePlanReviewYes
Description
**HILLSIDE** **W.U.I. HILLSIDE ZONE A CLASS "A" ROOF AND NON-COMBUSTIBLE EXTERIOR SIDING REQUIRED** **PRESCRIPTIVE ENERGY REQUIREMENTS** Permit for the construction of a new 3292 sq. ft., two story (first story 2048 sq. ft., second story 1244 sq. ft.) single family dwelling with 3 bedrooms, 4 bathrooms, approximately 321 sq. ft. of covered patio/porch and a 637 sq. ft. attached garage per the approved plans and any notations. SP-01 zoning and setbacks per planning. JJN. NO FIRE SPRINKLERS REQUIRED.
A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at 208-608-7168 with questions.

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Melissa Jannusch at 208-608-7168.

The final inspection of the site grading and drainage work shall be done by the design engineer. Written approval shall be submitted to Boise Public Works prior to the issuance of the building final.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final4/17/20204/17/20204/17/2020PPASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Kyle Seick
DOC - Permit Finaled4/17/20204/17/20204/17/2020PPASS
DetailsBrandon Shaw
BLD-Blower Door Test Results4/17/20204/17/20204/17/2020PDONE
DetailsBrandon Shaw
ACH50- 3.96
BLD-Final4/16/20204/17/20204/17/2020ACANC
DetailsBrandon Shaw
Phone #: ###-#### >> Inspection requested via web by Kyle Seick Inspection cancelled from web by: Kyle Seick
BLD-Other1/13/20201/14/20201/14/2020APASS
DetailsBrandon Shaw
Soffit. Phone #: ###-#### Inspection requested via web by Kyle Seick
BLD-Energy code compliance1/10/20201/10/20201/10/2020PPEND
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Kyle Seick
BLD-Framing/Rough-in1/9/20201/9/20201/9/2020PFAIL
DetailsBrandon Shaw
See pgs S1.1 & S2 for details and plan notes- red marks- for corrections...
A35 clips
Trimmer studs
Column and king studs...
OK to insulate...
BLD-Framing/Rough-in1/7/20201/8/20201/8/2020ANR
DetailsBrandon Shaw
Need mech ruogh-in...
Provide truss Engineering...
BLD-Wall Bracing12/17/201912/17/201912/17/2019PPART
DetailsBrandon Shaw
1st floor only...
Work in progress...
BLD-Foundation10/22/201910/22/201910/22/2019PPASS
DetailsBrandon Shaw
Work in progres...
BLD-Footing10/21/201910/21/201910/21/2019APASS
DetailsBrandon Shaw
Work in progress...