Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberBLD19-03643
StatusFinaled
Name POND TYLER G
Site Address 10606 W CRUSER DR
Project NamePond Home
Customer Number 
ePlanReviewNo
Description
Permit for the construction of a new 2574 sq. ft., one story single family dwelling with 4 bedrooms, 3 bathrooms, approximately 403 sq. ft. of covered patio/porch and a 833 sq. ft. attached garage per the approved plans and any notations. Prescriptive Energy Compliance. R-1C zoning and setbacks per planning. ***RDP***
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final8/5/20208/7/20208/7/2020APASS
DetailsMike Jordan
Ok with video/photo // Tyler Phone #: ###-####
DOC - Permit Finaled8/7/20208/7/20208/7/2020PPASS
DetailsMike Jordan
All issues were resolved..
BLD-Final8/4/20208/5/20208/5/2020APEND
DetailsMike Jordan
Tyler- */Screened*/ Phone #: ###-####. Needs to provide ignition barrier or DC coating to achoeve ignition barrier per the ESR report.
BLD-Energy code compliance5/14/20205/14/20205/14/2020PPASS
DetailsMike Jordan
Screened- Tyler Phone #: ###-####
BLD-Framing/Rough-in5/12/20205/12/20205/12/2020PPASS
DetailsMike Jordan
screened // Tyler Phone #: ###-####
BLD-Framing/Rough-in4/21/20204/22/20204/22/2020APASS
DetailsMike Jordan
screened // Tyler Phone #: ###-####. Framing issues in garage resolved. Ok to rock garage only.
BLD-Framing/Rough-in4/20/20204/21/20204/21/2020AFAIL
DetailsMike Jordan
Screened-Tyler Phone #: ###-####. Nail off all simpson hangars. Nail off 3ply girder in garage per the engineering, plys not in contact. Complete lateral bracing on A01 thru A08 trusses. Fireblock common wall in garage with master at ceiling level. Correction notice posted. This framing inspection is for garage only.
BLD-Framing/Rough-in3/4/20203/4/20203/4/2020PCANC
DetailsMike Jordan
anthony Phone #: ###-####
BLD-Wall Bracing3/4/20203/4/20203/4/2020PPASS
DetailsMike Jordan
anthony Phone #: ###-####
BLD-Foundation10/29/201910/30/201910/30/2019APART
DetailsMike Jordan
Call prior to going Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo aggregate constru
BLD-Footing10/28/201910/29/201910/29/2019PPASS
DetailsMike Jordan
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo aggregate constru
BLD-Footing10/27/201910/28/201910/28/2019ACANC
DetailsMike Jordan
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo aggregate constru Inspection cancelled via mobile web on Monday, October 28, 2019.
BLD-Footing10/28/201910/28/2019 P 
Details