BLD-Final | 6/17/2020 | 6/18/2020 | 6/18/2020 | P | PEND |
Mike Jordan
|
|
|
Sean *screened* Phone #: ###-####. Needs electrical, public works and zoning finals first. Ok to final after listed final inspections have been completed.
|
BLD-Energy code compliance | 3/12/2020 | 3/13/2020 | 3/13/2020 | P | PASS |
Mike Jordan
|
|
|
Sean Phone #: ###-####
|
BLD-Framing/Rough-in | 3/9/2020 | 3/11/2020 | 3/11/2020 | P | FAIL |
Mike Jordan
|
|
|
Justin Phone #: ###-####. Foam top plate penetrations above electrical service. Nail off TJI web stiffeners per the plan. Pressure block 2x4 top chord handstack at front of garage. Correction notice posted. Ok to insulate.
|
BLD-Framing/Rough-in | 2/18/2020 | 2/18/2020 | 2/18/2020 | P | NR |
Dave Hannah
|
|
|
Sean Phone #: ###-####
|
BLD-Wall Bracing | 2/18/2020 | 2/18/2020 | 2/18/2020 | P | PASS |
Dave Hannah
|
|
|
|
BLD-Foundation | 12/5/2019 | 12/5/2019 | 12/6/2019 | P | PART |
Tony Young
|
|
|
concrete at 2 // Brandon Phone #: ###-####
|
BLD-Footing | 12/5/2019 | 12/5/2019 | 12/6/2019 | P | PASS |
Tony Young
|
|
|
Brandon Phone #: ###-####
|
BLD-Footing | 12/4/2019 | 12/4/2019 | 12/5/2019 | P | PASS |
Tony Young
|
|
|
Brandon Phone #: ###-####
|
BLD-Footing | 12/3/2019 | 12/4/2019 | 12/4/2019 | A | PEND |
Tony Young
|
|
|
Brandon Phone #: ###-####// needs hillside approval
|
BLD-Footing | 12/3/2019 | 12/3/2019 | 12/4/2019 | P | PEND |
Tony Young
|
|
|
Brandon Phone #: ###-####,, ok pending soils approval
|